Corrections for Pull
If pull applied whereas standardising the length of tape and in the field pull applied are different, this correction is needed.
Let, P0 = Standard pull
P = Pull applied in the field
A = Cross-sectional area of the tape
L = Measured length of line.
E = Young's modulus of the material of tape, then
Above expression takes care of sign of the correction also.