Many types of decorative lights are connected in parallel. If a set of lights is connected to a 110 V source and the filament of each bulb has a hot resistance of 2.2 k Ω, what is the current through each bulb? Why is it better to have these bulbs in parallel rather than in series?
What is resistance?Explain the term resistance combination?
Two heating elements which is 500 Ω and 250 Ωare connected in series with temperature coefficient of 0.001 and0.003 Ω per oC, respectively at 20oC. Calculate the effective temperature coefficient of the combination.
Two random variables have zero mean and variance of 16 and 36. Their correlation coefficient is 0.5. A). find the variance of the sum. B). find the variance of their difference C). Repeat (a) and (b) if the correlation coefficient is -0.5
A filamentary conductor is formed into an equilateral triangle with sides of length l carrying current I. Find the magnetic field intensity at the center of the triangle.
Determine the N-point DFT X[n] of the N-point sequence x[n]=sin(ωon), 0≤n≤N-1, for ωo ≠ 2∏r/N, where r is an integer in the range 0
Given that the capacitance of the plates is 4 nF, sketch the current flowing through the plates.
A two port amplifier has been designed to match the source and load resistances Rin = 1k ohms, Rout = 16 ohms, A = 50dB. What is the amplitude of the input signal needed to deliver 1W to the 16 ohm resistor.
A certain transmission line is 10 meters long. Measurements indicate that the total inductance of the cable is 16 H. Standing wave measurements indicate that the voltage reflection coefficient at the load is 0.5 + j0 when a 75 ohm resistor
With the switch closed, find the real power P, reactive power Q, and apparent power S supplied by the generator. What is the power factor of the generator?
What is the charge density on the surface of the middle sheet facing the right sheet?
A dc shunt machine is connected to 220 volt supply and is running at speed of 1200 r.p.m . its armature current is 60 amp and the torque of its shaft is 95 Nm . show whether the machine in running as a motor or generator.
Calculate the short-circuit current in the feeder and the voltage of the 400 V busbars when a symmetrical three-phase fault occurs at the far end of the feeder. That fault level of the 11 kV system is 100 MVA.