What should be the concentration of pollutant

Assignment Help Civil Engineering
Reference no: EM13555150

A lagoon with volume 1,200 m3 has been receiving a steady flow of a conservative waste at a rate of 100 m3/day for a long enough time to assume that steady-state conditions apply. The waste entering the lagoon has a concentration of 10 mg/L. assuming completely mixed conditions,

(a) What should be the concentration of pollutant in the effluent leaving the lagoon?

(b) If the input waste concentration suddenly increased to 100 mg/L, what the concentration in the effluent be 7 days later?

C)A Nonconservative of pullutant with rate constant k=0.20/d.

Reference no: EM13555150

Questions Cloud

Determine the liquid limit of this clay : The following results were obtained from a liquid limit test on a clay using the Casagrande cup device.
Determine lengths l1 and l2 so the two materials elongate : A solid cylinder of 50 mm diameter and 900 mm length is subjected to a tensile force of 120kN. One part f the cylinder L1 long is of steel, the other part
What is the percentage error in the bulk unit weight : What is the percentage error in the bulk unit weight if the soil is the percentage error in the bulk unit weight if the soil is 95% saturated but assumed to be 100% saturated?
What must be the allowable elongation : A cylindrical rod of brass alloy (E = 100 GPa,) having a yield strength of 345 MPa is to be subjected to a load of 7500 N. If the length and diameter of the rod are 338 mm and 7.55 mm respectively, what must be the allowable elongation?
What should be the concentration of pollutant : A lagoon with volume 1,200 m3 has been receiving a steady flow of a conservative waste at a rate of 100 m3/day for a long enough time to assume that steady-state conditions apply. The waste entering the lagoon has a concentration of 10 mg/L. assuming..
With what velocity will air enter the room under : Laboratories containing dangerous materials are often kept at a pressure slightly less than ambient pressure so that contaminants can be discharged through an exhaust system rather than leaked through cracks and around doors to other parts of the bui..
What concentration of ozone should be injected : Ozone is sometime used as a disinfectant for drinking water. Ozone is highly reactive it will react benign species found in water, as well as the pathogens it is intended to kill.
Determine the percentage increase in the discharge : As part of a drainage improvement project, a drainage ditch will be straightened and cleaned. As a result, the lenght of the ditch will decrease from 1800 ft to 1400 ft and the mannings roughness factor will be reduced
What will be the porosity of the mixture : You are furnished with three sizes of particles. One is gravel with porosity of 0.32, the second is a coarse grained sand with porosity of 0.37, and the third is a fine grained sand with porosity of 0.23. If the coarse grained sand

Reviews

Write a Review

Civil Engineering Questions & Answers

  Engineering ethics and ethical issue

what is the engineering ethics course where to write about any engineering ethical case and discuss the ethical issue?

  Engineering ethics and concept and cases

what is the engineering ethics case related to civil engineering with reference and discuss all the engineering ethics issues which covered the "Engineering etics concepte and cases?

  Transportation and management

In the construction management, there is a lot of procurement route that are necessary and suitable for the construction industry.

  Supporting Investment Promotion: ERNST & YOUNG

Ernst & young is currently providing support to various sectors. In this regards it was felt that if this report is able to document good practices currently being adopted or planned in ceramic sector.

  Personalized Cancer Therapy-A step forward

Cancer is the uncontrolled growth of abnormal cells in the body resulting in tumours that can be benign or malignant (cancerous cells). A proper treatment is necessary to fight with this serious disease.

  Discuss the different environmental companies

Discuss the different agencies, institutes, centers, different environmental companies that are active in UAE.

  Develop a simple urban constructed wetland design

Develop a simple urban constructed wetland design.

  Evaluate company performance in relation to GRI standards

Evaluate company performance in relation to GRI standards and comment on Stigler's theory.

  Water system design

Determine the corresponding error in the computed discharge

  Hydraulic behaviour in open channel

Describe how test flumes and associated equipment are used to assess and confirm hydraulic behaviour in open channel

  Write a paper on steel sustainability

Write a paper on steel sustainability.

  Writing case study about bridge collapse

Writing case study about bridge collapse

Free Assignment Quote

Assured A++ Grade

Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!

All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd