Compute the response of a spring-mass system modeled by equation (2.2) to a force of magnitude 23 N, driving frequency of twice the natural frequency, and initial conditions given by x0 = 0 m and v0 = 0.2 m/s.
The mass of the system is 10 kg, the spring stiffness is 1000 N>m, and the mass of the spring is considered and known to be 1 kg.
What percent does the natural frequency change if the mass of the spring is not taken into consideration
problem 1a plane stress element is subjected to stress componentssigmax 50 mpa sigmay -10 mpa and tauxy 40 mpa.1
A force P in the xy-plane acts on the triangular plate. The moments of P about points O, A, and B are MO =80 N · m counter clockwise, MA =200 N · m clockwise, and MB =0. Determine P.
A tank of compressed air is at 40°C and 10 atm. 1 third of the gas is removed for inflating a car tire. The tank is allowed to exchange heat with the surroundings to maintain its temperature at all times. What kind of a process is this? What is the p..
What gas pressure will the experimenter measure inside the bulb, A glass bulb contains air at room temperature and at a pressure of 1 atmosphere. It is placed in a chamber filled with helium gas at 1 atmosphere and at room temperature
Air enters the evaporator section of an air-conditioner at 100 kPa, 27 C with a volumetric flow rate of 6 m^3 /min. R-134a enters the evaporator at 120 kPa with a quality of 0.3 and rate of 2 kg/min and it leaves as a saturated vapor at the same pres..
Consider a spherical container of inner radius r1, outer radius r2, and thermal conductivity k. Express the boundary condition on the inner surface of the container for steady onedimensional conduction for the following cases: (a) specified tempe..
Compare the ideal COP of R-134a and R-22 at an evaporating temperature of 40 F and 20 F superheat and condensing temperature of 120 F with 15 F sub cooling with the actual compressor COPs calculated from the manufacturer's performance tables.
a steam seperator seperates a 6 mpa saturated steam mixture into two streams whose pressure is the same as at the
You have a 120 Ω quarter bridge 2 wire set up with Sg=2.10 and an unknown lead wire resistance. A 59880Ω calibration resistor is switched in parallel to the gage only and a recording instrument is set to give a -100 mm deflection for this calibrat..
Refrigerant-134a at -12°C, in which 2.55kg of the refrigerant is in the liquid phase. An electric switch is turned on, and a 110-V source supplies current to a resistance heater inside the cylinder for a period of 20 minutes until the volume is doubl..
a venturi meter has an inlet of 250 mm and a throat of 150 mm diameter. its coefficient of discharge is .985. calculate
a solid shaft l 1.9 m long is supported between two bearings. the shaft rotates at 250 rpm. a 20 degree involute gear