Reference no: EM13495375 , Length: 10
1. It is necessary to measure the electrical conductivity of a process solution which is prone to deposit on surfaces. Discuss the application and maintenance aspects, with technical explanations and diagrams as necessary, to show how your proposed solution operates.
2. (a) The calibration techniques for cells for measuring conductivity, pH and other ion-selection electrodes are quite different.
Explain these differences.
(b) What is the effect of immersion depth on a glass electrode?
3. What aspects of the design of a pH electrode installation would lead to reduced manual maintenance and improved reliability? Give detailed descriptions of techniques as necessary.
4. (a) An infrared gas analyser has a span of 0 - 1% of the component being measured. It operates at atmospheric pressure and was calibrated when the barometric pressure was 0.995 bar.
The barometric pressure changes to 1.015 bar. What will the
instrument read when the actual percentage of the component is
(i) 0.5%
(ii) 0.8%?
(b) A sample of gas, which is to have one component measured by IR absorption, contains another component whose absorption spectrum seriously overlaps that of the wanted component.
(i) Why might this matter?
(ii) When it does, there are ways of clearing the system to make the measurement possible. Explain these techniques, mentioning any disadvantages.
(c) In an IR gas analyser, a 10 cm tube lets through about 70% (a reduction of 30%) of the radiation absorbed at full scale by the component being measured. Why would a longer tube be better and how much longer would be ideal?
5. (a) What methods are used in infrared, ultravoilet, and visible light systems to reduce the effects of deposition on windows and sample tube walls.
(b) Explain why is it increasingly possible to use mass spectrometry for on-line process applications.
Why might an ecd be preferred to a tcd as a detector
: What methods are used to achieve low levels of corrosion by oxygen in boiler feed water? What measurements are essential to ensure that this is done satisfactorily, and what types of measurement could be used?
|
Explain how times faster will the reaction occur
: the activation energy is 18 kj/mol and the overall delta E is -136 kj/mol. How times faster will the reaction occur at 50C than at 0C for the forward reaction
|
Analyze the common size income statements
: Analyze the accounts receivable and allowance for doubtful accounts changes and provide plausible explanations for the results.
|
How much energy is dissipated by dissipative forces
: A 1200 kg car is traveling at a constant speed of 13 m/s up a hill that makes a constant angle with the horizontal. How much energy is dissipated by dissipative forces in one second
|
What is the effect of immersion depth
: What is the effect of immersion depth on a glass electrode and what aspects of the design of a pH electrode installation would lead to reduced manual maintenance and improved reliability
|
Find the area of the region enclosed
: 1.Find the area of the region enclosed between y=2sin(x) and y=4 cos(x) from x=0 to x=0.6pi.
|
Estimate the capacitance of the second capacitor
: A capacitor is connected across the terminals of an ac generator that has a frequency of 424 Hz and supplies a voltage of 26 V. Find the capacitance of the second capacitor
|
Expalin reaction before the equivalence point
: a.)100 mL of 1.00 M HCl solution is titrated with 1.00 M NaOH solution. You added the following quantities of 1.00 M NaOH to the reaction flask. Classify the following conditions based on whether they are before the equivalence point
|
Determine changes in composition of a fluid
: What information has to be obtained in order to ensure that the method will be a satisfactory one and determine changes in composition of a fluid. Define what is meant by refractive index, and give the relationship between the incident and refracte..
|