What is the dry unit weight, the saturated unit weight, and the buoyant unit weight, of a soil having a void ratio of 0.5 and a value of Gs of 2.7?
Sketch a streamline, pathline, and streakline, For a given flow the velocity from time t=0 to t=5s was u=2 m/s, v=0. Then from t=5s to t=10s the velocity was u=+3 m/s, v=-4 m/s. A dye streak was started at t=0
A 2-inch diameter glass pipe is connected to a pipe network in which the pressure is 70 psig. If the length is 300 ft and the outlet is 10 ft above the pipe, determine the flow rate.
From a photograph one observs that on a level section of highway 20% of the vehicles are trucks, 80% are cars, and that there are 50 vehicles per mile of highway. The trucks travel at 40 mph, the cars at 50 mph.
A three-span continuous beam ABCD with three equal spans supports a uniform load with intensity q. Determine all reactions of this beam and draw the shear force and bending moment diagrams labelling all critical ordinates.
A rectangular channel is 25ft wide and has a flow of 500 cfs at a velocity of 5ft/s. (a) Determine the specifc energy of water in the channel. (b) What is the criticl depth of water in the channel (c) What is the critical velocity
A small chunk of the original sample had a wet weight of 140.9 grams and weighed 85.2 grams after drying. Compute the water content, using the correct number of significant figures.
Incandescent light bulbs have been phased out in the US because they are very inefficient (i.e., they produce a very large amount of heat). A 10 W light-emitting diode lamp (LED) can produce about the same light output as incandescent light bulbs
Water flows in a circular pipe of diameter D at a depth y (
A plate storage system for a self-serve salad bar in a restaurant. As plates are added to or withdrawn from the stack, the spring force and stiffness are such that the plates always protrude above the tabletop by about 60 mm.
A 600 MWe power plant has an efficiency of 36% with 15% of the waste heat being released to the atmosphere as stack heat and the other 85% taken away in the cooling water.
Complete a maximum demand calculation for a fully air conditioned hospital with the following electrical equipment and outlets. 500, 28W lamps 200, 14W lamps 400, 10A socket outlets 5, 18A, 3 phase, air conditioning units
(i) volume to supply the peak demand of 1.8 times the average demand. (ii) volume to supply fire flow for at least 9 hours, and (iii) volume to supply emergency storage 600 L/day/capita. (1 L = 0.001m^3)