Ethylene is produced by the dehydrogenation of ethane. If the feed includes 0.5 mol of steam (an inert diluent) per mole of ethane and if the reaction reaches equilibrium at 1100 K and 1 bar, what is the composition of the product gas on a water-free basis?
The viscosity of the liquor is 0.7 mN m-2 s. The cutoff crystal size required is 5 μm. Select a suitable type of centrifuge to use for this duty.
Determine the concentration of the exhaust gas and Determine the flow rate of exhaust gas through the smokestack.
Draw a schematic diagram for this control system. On your diagram, identify the controlled variables, manipulated variables, and disturbance variables. Be suit to include several possible sources of disturbances that can affect room temperature.
Make a practice HAZOP study of the plant section and add any instrumentation that is needed to develop the full P and I diagram.
question 1suppose the system shown below. initially the gas is at 200 kpa and occupies a volume of 0.1 m3. the spring
A horizontal heat exchanger has seven steel tubes enclosed in a shell having an ID of 5.0 in. The OD of the tubes is 1.0 in., and the tube wall thickness is 0.10 in. Pure ethyl alcohol flows through the 1.0-in.-OD tubes.
Does this distribution fit a normal distribution curve?
thermometry is the science of temperature measurement.nbsp for a thermometer to work we infer the temperature from the
A W12x22 structural steel wide-flange section of ASTM A36 steel is used as an axially loaded column. Find the allowable axial compressive load using Euler's formula and a factor of safety of 2.0. The column is pin connected at both ends and is 15 ..
Conversion is 96%, CAo=CBO=1 mol./lit. If a Mixed reactor tentimes as large as the PFR were hooked up in series with the existing unit, which unit shouldcome first and by whatfraction could productivity be increased for that setup?
In a device to produce potable water, humid air at 90°F, 29.7 in Hg, and 95% relative humidity iscooled to 40°F at constant pressure. What volumetric flow rate of air into the cooler (ft3/min) isrequired to provide 10.0 gal/min of condensed water?
Explain how you arrived at your answer, and show all steps you undertook.
Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!