What is the 555 timer ? and what is Working Principle of it ? wiht explanation of the 8 pins of 555 Timer
A 2N3904 has a power dissipation of 625mW without a heat sink. If the ambient temperature is 65 degree C, what happens to the power rating
Develop a Sensor Circuit using commodity component and design a wireless sensor node using commodity wireless modules
Discuss why it is important to understand how interpret data from op amp datasheets. How might this skill be used when designing op amp circuits.
1) What is the dynamic range for an 8-bit ADC 2) A device that responds to a small current or voltage change by activating a mechanical switch allowing a larger amount of current flow is a: a) transistor. b) transducer. c) solenoid. d) relay.
Which transistor bias circuit arrangement provides good Q-point stability, but requires both positive and negative supply voltages.
1. The closed-loop transfer function of a system is T(s) = 11.1(s +18)/ ((s + 20)(s2 + 4s +10)) Plot the poles and zeros of this system and discuss the dominance of the complex poles. What overshoot for a step input do you expect
Three screws are drawn at random from a lot of 100 screws, 10 of which are defective. Find the probability that the screws drawn will be nondefective in drawing (a) with replacement, (b) without replacement.
A low pass filter has a cut-off frequency of 8 kHz and a high pass filter has a cut-off frequency of 5 kHz. These two circuits are connected back to back in cascade to form an input-output system. How does this combination work, band pass or band ..
Design a synchronous 2-bit, binary, up-counter using the following specification: The counter has five inputs ( not including the clock) and three outputs. The inputs are CLR ("Clear"), LOAD, COUNT, LB and LA.
Write down the principle of energy conversion and give an example for single and double excited system.
What are the rated full -load speeds of a 400HZ motor that may be connected for either two or four pole operation, assuming a full load slip of 4% for both cases
A 60 kVA, three-phase, wye-connected, 440 V, 60 Hz synchronous generator has a resistance of 0.15ohm and a synchronous reactance of 3.5ohm per phase. At rated load and unity power factor, calculate the percent voltage regulation.