The Ozzie Outback Electric Power (OOEP) Company maintains the power system shown in Figure. This power system contains five busses, with generators attached to two of them and loads attached to the remaining ones. The power system has six transmission lines connecting the busses together, with the characteristics shown in Table 13-1. There are generators at busses Bunya and Mulga, and loads at all other busses. The characteristics of the two generators are shown in Table 13-2. Note that the neutrals ofthe two generators are both grounded through an inductive reactance of 0.60 pu. Note that all values are in per-unit on a 100 MVA base.
(a) Assume that a single-line-to-ground fault occurs at the Mallee bus. What is the per-unit fault current during the subtransient period? during the transient period?
(b) Assume that the neutrals of the generators are now solidly grounded, and that a single-line-to- ground fault occurs at the Mallee bus. What is the per-unit fault current during the subtransient period now? during the transient period?
(c) Assume that a line-to-line fault occurs at the Mallee bus. What is the per-unit fault current during the subtransient period? during the transient period?
(d) How much does the per-unit fault current change for a line-to-line fault if the generators are either solidly grounded or grounded through an impedance?
Table 13-1: Transmission lines in the OOEP system.
From
To
RSE , pu
X
1 , pu
X 2 , pu
X0 , pu
Bunya
Mulga
0.011
0
.051
0.051
0.090
Satinay
0.007
.035
0.035
Myall
0.060
Mallee
0.110
Table 13-2: Generators in the OOEP system.
Name
Bus
R (pu)
XS (pu)
X'(pu)
X" (pu)
X2 (pu)
Xg0 (pu)
XN (pu)
G1
0.02
1.5
0.35
0.20
0.10
0.60
G2
0.01
1.0
0.25
0.12
0.05
Figure- The Ozzie Outback Electric Power Company system.
A 100 Hz electromagnetic wave is propagating down into the sea water with an electric field intensity of |E| = 1 V /m just beneath the sea surface. What is the time-average Poynting power density at a depth of 100 m
where can i find a copy of the answers to textbook review questions in the industrial motor control 6 th edition by
A certain sawtooth generator has the following parameter values: Vin: 3v, R: 4.7kohm, C:0.001uf. Determine its peak-to-peak output voltage if the period is 10 us. What is the Vpp
There are 15 randomly selected Multiple Choice questions
the rms voltage of a balanced 3 phase Y connected source is 110 volts at 60Hz. it is connected to a balanced Y Load by 3 distribution lines with an impedence on each line z=1+j2. the load impedence is z=19=j28 per phase.
What is the common-mode rejection ratio (in dB) if the output voltage is measured to be 2.0 Vp-p when the input terminals are connected together and a 0.1 Vp-p voltage is applied between the inputs and ground.
In a MOS cascode amplifier, the cascode transistor is required to raise the output resistance by a factor of 40. If the transistor is operated at Vov = 0.2 V, what must its Va be. If the process technology specifies V'a as 5 V/um, what channel len..
The function f(t)=3cos(500πt) + 5cos(800πt) issampled digitally at a sampling rate of 400 Hz, starting attime t = 0.00025 s. (a)Calculate the frequencies that you would expect to see on afrequency spectrum of the sampled data.
suppose i have a charge on an insulator. if i touch it to a conductor what happens? since charge doesnt flow on
Is there any easy way to understand nodal analysis with voltage source and direction of current Where to start studying from if there is problem with understanding concepts
A lighting load operates from a 208-V 60-Hz supply and is rated 1.0 kW with a power factor of 0.9 lagging. A 40-µF capacitor is connected in parallel with this load. Calculate the total power factor and the percent change in line current.
Design an amplifier using a JFET and a 20V power supply. Calculate the required resistor and capacitor values for the circuit, assuming a minimum frequency of 10 Hz.