What electrical code is universally used in the United States?
Identify three types of equipment that may require three-phase power.
Identify the type of cable that is permitted in single- and multifamily dwelling units but that cannot be used underground, nor in buildings that are more than three stories above grade, nor in commercial garages, motion picture studios, theaters, places of assembly, elevator hoist ways, and other corrosive or hazardous locations.
Identify the type of cable permitted in direct-burial applications such as a feeder or branch circuit provided it is protected by an overcurrent protection device (fuse or circuit breaker) before it leaves the panelboard.
What functions must the communications stations perform? Repeat for ring and star.
Design a 4 input, 1 output combinational circuit. the input represents a 4-bit number, N = X3X2X1X0, which ranges from 0 to 15. The output, PN is 1 when N represents a Prime Number,PN, otherwise PN is 0
Show the design of a 2-1 Mux: (a) using a NAND/NAND implementation, (b) using a NOR/NOR implementation. Which would you prefer to build and why Assume that you have all variables and their complements available.
calculate the average signal-to-noise (SNR) in decibels (dB) Assume equal numbers of binary 0s and 1s.
A)Design a high-pass filter with a cutoff frequency of 40 kHz. Use 0.01 uF capacitor and an appropriate resistor. B) Sketch and label the circuit. C) What is the gain of the filter at the cutoff frequency Give your answer both as ratio (Vout/Vin) ..
For the depletion-load amplifier, let W1=80microm, L1=4micrometers, W2=8 micrometers and L2=32 micrometers. If the body-effect parameter X=0.2, find the voltage gain neglecting the effect on ro.
A unit for a telecommunications system is to be designed so as to have a minimum availability of 0.9994. The MTTR (mean time to repair) for the unit is estimated to be 24 hours.
Describe why interrupts are not appropriate for implementing synchronization primitive in multiprocessor systems.
compute the power loss in a transmission line with a resistance of 0.05 ohms/mile. Compute the power loss if 500kW of power is transmitted from a power generating station to cities at distances of 20,30,40....100 miles at 100v and 200v.
Consider LTI system S with impulse response h(t) = u(t) - u(t-2). A) Let x1(t) = d/dt(u(t) - u(t-2)). What is the output of the system B) Let x2(t) = cos(pi*t). What is the output of the system
At the output of a two terminal DC network, when no load is attached , the voltage measured as 6 volts. When a load of 1 kiloohms is connected across output, the voltage at the output drops to 4 volts. Create a Thevenin Equivalent model of this ne..
Using a shorted stub to match load, what is the lenght of the line where the normalized input Y is 1 + jb . If the characteristic impedance of the shorted line is 40 ohms, what is the length of the stub length.