Hot, moist outside air passes over a cooling coil, from which it exits in a saturated state at p=14.7lbf/in^2 and T=65F. The air is then mixed adiabatically with room air at p=14.7lbf/in^2, T=75F, phi=25%. The mixing process occurs at constant pressure. The dry air mass flow rate leaving the cooling coil is 250lbm/h, and the dry air mass flow rate entering the mixing chamber from the room is 750 lbm/h. Using the psychometric chart, determine the following:
i) the humidity ratio leaving the cooling coil
ii) the humidity ratio leaving the room
iii) the humidity ratio leaving the mixing chamber
iv) the final mixed air temperature (F)
v) the final mixed air relative humidity
a powerplant is situated at an altitude of 1000 ft above sea level. flue gases enter the slack at 285 degree f and
five kilograms of water at saturated liquid phase fills in a piston-cylinder device at 150oc. the device is now heated
A 400 L rigid tank contains 5 kg of air at 25 degrees C. Determine the reading of the pressure gauge if the atmospheric pressure is 97 kPa.
how does the statistical mechanical definition of entropy allow a reinterpretation of the second and third law of
what is the effect of quenching on the transition temperature and toughness for the mild steel ?
two moist air streams flow into a modified cooling tower to cool liquid water from 120 f to 75 f. the first moist air
Air with a dry bulb temperature of 38°C and a dew point temperature of 20 °C is at a barometric pressure of 93.1 kPa. Without making use of the psychrometric chart for the given moist air determine the relative humidity
0.65m^3 rigid vessel initially contains saturated liquid vapor mixture of water at 150C. The water is now heated until it reaches the critical state. Determine the mass of the liquid water and the volume occupied the liquid at the initial state.
calculate the transverse modulus of the peek/carbon fiber composite with 30% volume fraction by tow method. the modulus of peek is 3.8 GPa and the modulus of the carbon fiber is 400GPa. assume the reinforcing factor.
air is heated at steady state as it flows through a constant area duct. at the inlet the pressure is 2.8 bar the
In a reheat rankine cycle, steam enters the turbine at 4 MPa and 400 C. After expanding to 400 kPa, the steam is reheated again to 400 C, and expands in the low pressure turbine to 10 kPa. If the efficiency of the turbine and the pump is 100% and the..
For a laminar flow between two parallel plates shown figure below, obtain an expression for the pressure drop and velocity profile. Also, obtain an expression for Frictional dissipation and the friction factor.
Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!
whatsapp: +1-415-670-9521
Phone: +1-415-670-9521
Email: [email protected]
All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd