Tank that is initially evacuated is connected by a valve to

Assignment Help Mechanical Engineering
Reference no: EM13624844

Tank that is initially evacuated is connected by a valve to an air supply line flowing air at 20 degree C, 800 kPa. The valve is opened, and air flows into the tank until the pressure reaches 600 kPa. Determine the final temperature and mass inside the tank, assuming the process is adiabatic. Develop an expression for the relation between the line temperature and the final temperature using constant specific heats.

Reference no: EM13624844

Questions Cloud

Sketch the steady-state temperature and heat flux : a composite rod consists of two different materials a and b each of length 0.5 l. the thermal conductivity of material
Steam flows steadily into a turbine with a mass flow rate : steam flows steadily into a turbine with a mass flow rate of 26 kgs and a negligible velocity at 6 mpa and 600 c. the
Sunlight strikes the surface of a lake a diver sees the : sunlight strikes the surface of a lake. a diver sees the sun at an angle of 28.4deg with respect to the vertical. what
What is the volume occupied by the water vapor what is the : a frictionless piston-cylinder is filled with 3 liters of water at 250 kpa. initially the temperature of the water is
Tank that is initially evacuated is connected by a valve to : tank that is initially evacuated is connected by a valve to an air supply line flowing air at 20 degree c 800 kpa. the
A ray of light in the coating is incident on the : a glass lens has a scratch-resistant plastic coating on it. the speed of light in the glass is 0.670c and the speed of
For a particular card game a standard deck of cards has all : for a particular card game a standard deck of cards has all of the aces kings queens and jacks removed. among the 36
An evacuated 150-l tank is connected to a line flowing air : an evacuated 150-l tank is connected to a line flowing air at room temperature 25 degree c and 8 mpa pressure. the
Draw the equipment and show the changes from the starting : saturated liquid ammonia is compressed adiabatically in a pistoncylinder. the ammonia starts at 40f and the

Reviews

Write a Review

Mechanical Engineering Questions & Answers

  At the beginning of the compression process p11bar and

he compressor ratio of an air standard otto cycle is 8. at the beginning of the compression process p11bar and t1300k.

  A house has a composite wall of plaster board lp 10mm k072

a house has a composite wall of plaster board lp 10mm k0.72 wm.k fibre glass insulation lb100mm k1.4 wm.k and plywood

  What is the allowable minimum length of the ramp

If the ramp height is 2ft. Using the ada code, what is the allowable minimum length of the ramp?

  The upper capor compression refrigeration system vcrs uses

a two stage cascade refrigeration system is to provide cooling at -40c while operating the high temperature condenser

  A 04 w cylindrical electronic component with a diameter of

a 0.4 w cylindrical electronic component with a diameter of 0.3 cm and length 1.8 cm is mounted horizontally on a

  Determine the work done by a 1-lb fluid system as it

determine the work done by a 1-lb fluid system as it expands slowly within a piston-cylinder arrangement from an

  The plate is 2m long and 2m wide the temperature of the air

air flows parallel to an isothermal 100c flat plate with a free stream velocity of 10ms and free stream temperature of

  Assume the roughness wavelength is 10m and its amplitude is

a car and its suspension system are idealized as a damped spring-mass system with natural frequency 0.5hz and damping

  What is the tension force in the container side-walls

a a team of astrononers have proposed to construct a large parabolic telescope mirror by spinning a cylindrical

  The power input to the steam is known to be 500 w determine

a refrigeration system is designed to operate between temperture limits of -10 c and 25 c. the power input to the steam

  At the diffuser exit the temperature is 430 k determine the

air enters an insulated diffuser at 260 k and 60 kpa with a velocity of 633.9 ms. at the diffuser exit the temperature

  The system contains a sharp-edged entrace 6 threaded 90

a liquid at 10 c kinematic viscosity of 1.30710-6 m2s is to flow from a roof-top reservoir to a tanker truck through a

Free Assignment Quote

Assured A++ Grade

Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!

All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd