Recording of the electrical activity of the heart

Assignment Help Electrical Engineering
Reference no: EM131070357

1. Electrocardiogram (ECG) is a recording of the electrical activity of the heart which is clinically utilized to monitor patients and diagnosis life threatening cardiac arrhythmias [1]. See Figure 1. Remote monitoring in a patient'shome or office could be used to alert medical personnel to intervene prior to a major cardiac event. These remote monitors have the ability for automated analysis utilizing a signal sampled up to 1000 Hz. The remote monitors would alert medical personnel if an life threatening cardiac event was imminent. Cardiologists are trained to read the ECG and provide the standard for diagnosis based on the ECG. The higher frequency components in the remote monitored ECG are not required for visually ECG interpretation. A reduction of the sampling rate would facilitate transmission to a physicians portable electronic device for immediate evaluation. Given an electrocardiogram acquired and recorded remotely at a sampling rate of 1,000 Hz, decrease the sampling rate to 125 Hz. Antialiasing filtering is required in digital as well as analog sampling. The 8 to 1 sampling rate reduction requires digital low-pass filtering prior to sample rate reduction to 125 Hz.

 

Figure 1: Electrocardiogram (12 lead) from a normal healthy individual. [https://en.wikipedia.org/wiki/Electrocardiography]

 

Figure 1 contains a 12 lead ECG presented in a typical format required for visual diagnosis. Figures 2 and 3 show the electrode placement for these leads. The augmented leads (aVR, aVL and aVF) are derived from the Einthoven limb leads (I, II, and III). Therefore, the ECG signals from the nine recorded limb (I, II, and III) and precordial leads (V1 - V6) are sufficient for transmission to a remote reader.

 

Given the recording in the MATLAB data file "recording 1 .mat" containing recording for (V1 - V6, I, II and III):

 

1. The recorded ECG magnitude in the structure array "Data.ECG" is in Volts, multiply each column in the array by 103 to convert the magnitude to mV. Reduce the sampling rate from 1000 Hz to 125 Hz for all nine ECG recordings without aliasing the signal. You can use the MATLAB "decimate" function to perform sample rate reduction. It has a built in antialiasing filter.

 

2. Display all nine sampled signals. Label the y-axis with its appropriate lead name which are stored in Data.Labels. Label the x-axis in seconds starting a zero. Include the units for both the x and y axes.

 

3. Find the spectrum of each lead in the recording using the MATLAB function "pwelch" which divides the data into segments and utilizes the FFT on each segment to obtain an estimate of the spectrum from the average of the magnitude of the FFT from all the segments. Use a window L=116 for pwelch.

 

4. Display the magnitude of the spectrum for each lead as dB vs frequency (Hz). Label each spectrum with its lead designation. Label both the y and x axes.

 

Reference no: EM131070357

Questions Cloud

What is the total distance the runner covered : One runnercompletes 10 laps of the race. What is the total distance the runner covered? What is the total displacement for the runner?
What is benefit of using a key-indexed array implementation : What is the benefit of using a key-indexed array implementation? Give a circumstance under which a key-indexed array implementation is inappropriate.
What percent have homozygous recessive genotypes : If we observe/survey our campus population and we observe that 75% of our subjects are right handed. What percent have homozygous recessive genotypes in our population
Determining the resistance of the resistor : What was the effect of reducing the resistance of the resistor on the way the capacitor discharged?
Recording of the electrical activity of the heart : 1. Electrocardiogram (ECG) is a recording of the electrical activity of the heart which is clinically utilized to monitor patients and diagnosis life threatening cardiac arrhythmias [1]. See Figure 1. Remote monitoring in a patient'shome or office..
What environmental factors may have helped : Speculate on what environmental factors may have helped bring about this change and explain how. Be creative, but use scientific explanations to explain the process
What are types of behaviors have primatologists observed : What are types of behaviors have primatologists observed among chimpanzees and bonobos
Define the following- culture and society : Define the following. Culture Society Ethnology Social stratification
What functions does social stratification serve : In your own words, define social stratification. What functions does social stratification serve? How do those in higher ranks use their status

Reviews

Write a Review

Electrical Engineering Questions & Answers

  Lithium ion battery technology

The paper includes Lithium ion battery technology with its advantages and disadvantages. The paper discusses about the Lithium air battery in which detailed reactions of Lithium with air including nonaqueous as well as aqueous are given.

  Power transformers and tariffs

Construction of different types of power transformer, significant energy savings

  Paper on orthogonal frequency-division multiplexing

This document is shown a paper on Orthogonal frequency-division multiplexing with advantages, disadvantages and uses.

  Function of the hmi in a scada system

This assignment contains electronics engineering questions like State the commonly found components of a SCADA (Supervisory control and data acquisition) system. and decribe the function of the HMI in a SCADA system.

  Resultant waveform of the odd harmonic series

Prepare an Excel graph showing the individual components and summated resultant waveform of the odd harmonic series resulting in an approximate square wave.

  Explain scada system

Explain the function of the HMI in a SCADA system.

  Design a 2-digit 24 second shot-clock

Design a 2-digit 24 second "shot-clock" countdown timer with pushbutton controller.

  Model a discrete-time system

To understand di erent signal models To be able to model a discrete-time system and design simple signal processing algorithms.

  Draw a relay construction diagram

Draw a relay construction diagram and briefly explain the operation of a relay.

  Frequency division multiplexing

Write a short technical report on Frequency Division Multiplexing

  Impact of electron energy

Briefly discuss the impact of electron energy, electron current and target on the Bremsstrahlung generated.

  Traffic light controller

The schematic of the traffic light controller

Free Assignment Quote

Assured A++ Grade

Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!

All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd