A new 1.3 m3 tank and ancillary equipment is to be installed in a hygienic food processing plant. The duty is to store a heat sensitive water based fluid at 25 degC for a period of 10 hours. The fluid has a high capital value, and is damaged if the fluid temperature drops below 20 degC, or exceeds 30 degC. Propose two equipment methods, in order of preference, to achieve the above duty, and outline the advantages and disadvantages of each method and the basis of your proposition.
nitrogen r0.2968 kjkg-k cv 0.745 kjkg-k at 100 kpa is contained in an insulated piston cylinder device as shown in the
steam enters a nozzle operating at steady state at 20 bar temperature 280c with a velocity of 80 ms. the exit pressure
if the bar has clockwise angular velocity of 10 rad/s and Va= 20m/s what are coordinates of instantaneous center of the bar, and what is the value of Vb?
a 50 kg copper block initially at 350 c is quenched in a closed rigid insulated tank containing 120 l of liquid water
What are the standard S.I. And English based units for reporting strain? What are the standard S.I. And English based units for reporting Youngs Modulus?
a flat-plate collector 4m2 in area is tested during the night to measure the overall heat loss coefficient. water at
determine the size of the contact patch the contact stresses and the maximum shear stress for a 40 mm diameter steel
an electromedical cell is composed of pure copper and pure lead electrode immersed in solution of their respective
a gas within a piston-cylinder assembly undergoes a thermodynamic cycle consisting of three processesprocess
a double pipe heat exchanger has an effectiveness of 0.5 when the flow is counter current and the thermal capacity of
a tank of 2m3 volume contains saturated ammonia at a temperature of 40c. innitially the tank contains 50 liquid and 50
a 1-mm-thick bcc iron foil is used to separate a region of high nitrogen gas concentration of 0.1 atomic percent from a