Consider the extraction of energy from the tail gases from a nitric acid adsorption tower.
Gas composition, kmol/h:
If the gases leave the tower at 6 atm, 25 °C, and are expanded to, say, 1.5 atm, calculate the turbine exit gas temperatures without preheat, and if the gases are preheated to 400 °C with the reactor off-gas. Also, estimate the power recovered from the preheated gases.
12. Comparing emitted Auger electrons (AES, Auger electron spectroscopy) with X-rays (EDX / EDS, energy-dispersive X-ray spectroscopy), what is the difference in the analysed sample volume (i.e. volume of the sample from which the signal comes)?
Determine the longest wavelength (in cm) of X-rays that is still capable of producing diffraction in copper, Cu.
The helicopter can produce a maximum downward air speed ( v = 24 m/s ) in a slipstream of a diameter ( D = 9 m). Knowing that the weight of the helicopter and the crew is ( 15 kN ) and assuming air density rho = 1.21 kg/m^3 ), determine the maximu..
A horizontal steel pipe having inner and outer diameter as 150 and 180 mm respectively is lagged with 50 mm thickness of 85% magnesia insulation inside ,which has flue gas flowing at 260oc
upon responding to a 200 a.m. domestic transportation mishap your hazmat team determines that a liquefied compressed
Van Laar equation to calculate activity coefficients, How do I use the Van Laar equation to calculate an activity coefficient for an equilibrium ethanol/water binary system with mole fractions of ethanol in liquid of
You have a heat pump that takes in 256 kW of heat and puts out 604 kW of heat. What is the coefficient of performance (C.O.P.) of the system ( express this value as a fraction)?
Strontium fluoride, SrF2, has a Kspvalue in water of 2.45 × 10-9at room temperature. Calculate the solubility of SrF2in water. Express your answer in units of molarity.
Estimate the annual operating cost of providing refrigeration to a condenser with duty 1.2 MW operating at -5 ºC. The refrigeration cycle rejects heat to cooling water that is available at 40 ºC, and has an efficiency of 80% of the Carnot cycle ef..
You are the project manager of a team that has been asked to complete the design of a chemical plant up to the stage of design selection. You have three engineers available (plus yourself) and the work must be completed in ten weeks. Develop a pro..
adsorption and membrane processeszeolites are used to adsorb a wide range of solutes from vapour and gas streams. what
Estimate the cost of the following items of equipment: a. A packaged boiler to produce 20,000 kg/h of steam at 40 bar