In the 3-Op Amp Instrumentation amplifier, all the resistor values are the same with the exception of RG which determines the gain. Is it possible to have additional gain at the output Op Amp of Rf/Rin?
A network connected between terminlas a and b consists of two parallel combinations that are in series. The first parallel combination is composed of a 10 OHM resistor and a 19 OHM resistor.
Determine the required-size THW copper conductor and overcurrent device rating required for a dedicated feeder supplying a 250 A noncontinuous linear load. Assume an ambient temperature of 30°C
In a motor control system, one master stop pushbutton (Stop) is available for stopping the operation at any time. If the temperature switch (TSW) is closed, pressing the red pushbutton (RedPB) will turn on both motors M1 and M2.
1) in a swamped common-emiter BJT amplifier, as shown below, if Vcc =12 V, R1 =8.2 kohm, R2=10 kohm, Rc = 500 ohm, Re= 1 kohm, Vbe = 0.7 V, and B =100, what is the transistor`s emitter current
Assume a house with 100 m2 of roof area. All the water runoff from the roof is collected into barrels of 55 gal capacity. The stored water is used to irrigate flower beds at the rate of 10 gal/day.
Draw the ROM truth table for the seven segment
Suppose station A and B are interconnected through two parallel unreliable links, where each link has a failure probability of 0.1. Calculate the average seconds per day when A and B lose communication.
Capacitance can be altered by immersing part of the two wire line into a different medium. (a) What is the capaccitance per unit length in F/m of the transmission lines. You must explain your reasoning and show the equation you used.
A 600/120V, 60Hz transformer has a primary resistance of 0.4 Ohm, reactance of 0.9 ohm and secondary has a resistance of 0.8 Ohm and reactance of 1.2 Ohm. Find the secondary terminal voltage when it is connected to a load of 1500W at 0.8 lagging p..
A half-wave rectifier circuit with a 1-k ohm load operates from a 120-V (rms) 60-Hz household supply through a 10-to-1 step-down transformer. It uses a silicon diode that can be modeled to have a 0.7-V drop for any current.
A 60 Hz, 765 kV three-phase overhead transmission line has four ACSR 1113 kcmil 54/3 conductors per phase. Determine the 60 Hz resistance of this line in ohms per km per phase at 50o C.
How a transformer works and apply those rules to a transformer where the primary core cross-sectional area is twice.