In a specific type of heat exchanger

Assignment Help Mechanical Engineering
Reference no: EM13710400

In a specific type of heat exchanger, a very hot jet of air is cooled from 145 degrees centigrade to 100 degrees centigrade by a cold stream of water. The water temperature must not rise By more than 12 degrees centigrade. Find 1. How much cooling water in kg/s is required to cool 2.5 kg/s of air and 2. What the rate of heat transfer between the two fluids is.

Reference no: EM13710400

Questions Cloud

The fugacities of ethane and n-butane in equimolar mixture : Compute the fugacities of ethane and n-butane in an equimolar mixture at 373.15K at 1, 10, and 15 bar total pressure assuming that the Lewis-Randall rule is correct.
How much water is needed-ignores change in kinetic energy : An ADIABATIC steam turbine works between inlet pressure of 100 bar and outlet pressure of 25 bar. The inlet temperature is 600 degrees Celsius. Outlet steam has a quality of 90 percent. You want to know if this facility is fit to generate your need o..
Heat transfer and work transfer for the two-step process : Ten pounds-mass of R-22 is at an initial volume of 4.059 ft3 and pressure of 200 psia. It is compressed isobaric ally until its volume is two-thirds of its initial volume. The piston is then held in place as the refrigerant cools until its temperatur..
Develop the skills to write a report : Develop the skills to write a report - One of the requirements of this course is to write a report.
In a specific type of heat exchanger : In a specific type of heat exchanger, a very hot jet of air is cooled from 145 degrees centigrade to 100 degrees centigrade by a cold stream of water. The water temperature must not rise By more than 12 degrees centigrade. Find 1.
What is the polytropic exponent of this process : Air, initially at 220 kPa and 450 K undergoes a polytropic state change to 374 kPa and 495 K. What is the polytropic exponent of this process? Saturated water vapor is contained in a rigid container. Heat is then added until the pressure and temperat..
What is the outlet to inlet area ratio of this diffuser : Design a ceiling diffuser. Air flows in the duct behind the diffuser and enters the diffuser at a pressure of 12.8psia, and a velocity of 200in/sec. The outlet of the diffuser is in the room, with atmospheric pressure of 14.5 psi. For the comfort of ..
Wedges-learning goal : The crate shown is held against wedge B by a spring. The spring is 94.5% of its original uncompressed length l=2.75m, and the spring constant is given as k=1650N/m. The coefficient of static friction at all contacting surfaces is ?s=0.130. The mass o..
Obtain the half-range cosine series for the function : A periodic function f(t)is of period 10 defined by f(t)=N+t2, 0

Reviews

Write a Review

Mechanical Engineering Questions & Answers

  What were the flaws in your experiment what sort of

what were the flaws in your experiment? what sort of reproducibility does your experimental procedure yield? 4. how

  Does the radius of the column matter

Concrete has a density of 2500 kg/m3 and a compressive strength of 30 MPa. What is the maximum height of a column of concrete that can support its own weight? Does the radius of the column matter?

  Consider a simple brayton cycle using air as the working

consider a simple brayton cycle using air as the working fluid has a pressure ratio of 12 has a maximum cycle temp of

  Some nitrogen is allowed to escape until the pressure in

a 20-m3 tank contains nitrogen at 23degc and 600 kpa. some nitrogen is allowed to escape until the pressure in the tank

  Water flows at 50oc inside a 25-cm-inside-diameter tube

water flows at 50oc inside a 2.5-cm-inside-diameter tube such that hi 3500 wm2 oc. the tube has a wall thickness of 0.8

  The device is not insulated and operates in an environment

a refrigeration engineer has designed a steady-flow no work interaction device that separates a continuous flow of 100

  Water vapor is cooled in a closed rigid tank from 520 c

water vapor is cooled in a closed rigid tank from 520 c and 100 bar to a final temperature of 270 c. determine the

  Steam enters diffuser operating steady state with pressure

Steam enters a diffuser operating at steady state with a pressure of 14.7 psi, a temperature of 300F, and a velocity of 500ft/s. Steam exits the diffuser as a saturated vapor with negligible kinetic energy. Heat transfer occurs from the steam to its ..

  Measuring fracture toughnessthe aim of this demonstration

measuring fracture toughnessthe aim of this demonstration is to use measurements of the load required to propagate a

  Draw a graph of system head and fluid power

Draw a graph of system head and fluid power against flow rate on one sheet of graph paper, using the values determined in(c)

  What is the output variable

A process with Gp= 2/(2s+1) and Gd=1/(2s+1) experiences a disturbance step change of magnitude 5. The SP remains constant. If a P-controller alone with Kc=1 is used and Ga=Gs=1, then what is the output variable, delta Y(t) versus time?

  Calculate the yield stress of the material

Calculate the yield stress of the material and the force required to produce yield - determine the bulk modulus of the material.