How to use amperes circuital law to find h everywhere for z

Assignment Help Electrical Engineering
Reference no: EM13253782

A current filament carrying I in the -az direction lies along the entire positive z. At the origin, it connects to a conducting sheet that forms in xy plane. a) Find k in the conducting sheet. b)use Ampere' s circuital law to find H everywhere for z>0 c) find H for z<0.

Reference no: EM13253782

Questions Cloud

Determine the line and phase voltage and phase current : A Y-connected load with an impedance of 12-j15 Ohms per phase is connected to a balanced Delta-connected 208V, 60Hz, three-phase, positive phase-sequence supply. Determine 1) the line and phase voltage, 2) the line and phase current
Define and discuss job analysis : Define and discuss job analysis. List and describe the steps in conducting a job analysis. What are some advantages and disadvantages of this technique?
How that plays a critical role in initial litigation process : personal or subject matter jurisdiction and how that plays a critical role in the initial litigation process.
Determine the prsent worth of the project : If the proportional amount of the loan is recieved at the beginning of each year, determine the prsent worth of the project assuming the units are produced sequentially.
How to use amperes circuital law to find h everywhere for z : A current filament carrying I in the -az direction lies along the entire positive z. At the origin, it connects to a conducting sheet that forms in xy plane. a) Find k in the conducting sheet.
Find approximate saturated synchronous reactance at current : A 25MVA, three phase, 13.5kV, Y-connected, two pole, 60Hz synchronous generator was tested by the open circuit test and short circuit test and tabulated in table 1. If the armature resistance is 0.24 ohms per phase.
Are the specifications being met : specifications for the computer upgrades in problem 4 are 78 minutes and 81 minutes. based on the date given in the problem, are the specifications being met?
Summarize the alleged violation : Include a minimum of three sources, which may consist of readings from the University Library, your text,other selections, and your own experiences.
Find the input power to the generator in horsepower nd watts : A 500-kVA, 60Hz, 5000V, Y-connected, 10 pole synchronous has internal parameters of Armature Resistance 1ohm amd Synchronous Reactance 10ohms. The generator is operating at rated values and 0.9 pf leading.

Reviews

Write a Review

Electrical Engineering Questions & Answers

  Computation the percentage second harmonic distortion

Calculate the percentage second harmonic distortion present in the output. Calculate the percentage error in the output voltage compared to its ideal value at the instant of time when t= 1/3200 seconds.

  Calculate the noise specification given snr

3. For a simulated inductor application, to yield L = 75mH, R1 = 3kohm, and C1 = 200uF, determine required value of R2 4. For a constant current generator, with a saturation voltage = 20V and a current reference of 30mA, calculate RLmin.

  Explain the shunt field resistance

A 240kW 500V 1750 r/min separately excited dc generator has an overall efiiciency of 94%. The shunt field resistance is 60 ohms and the rated current is 5A. The I^2 R loss in the armature is 0.023 pu.

  Explain power factor correction

Power factor correction, Three parallel impedances in rectangular form as follows

  Compute the approximate quantization

Calculate the approximate quantization S/N ratio in the baseband audio signal at the receiver output (after the DAC and LPF).

  Compute the equilibrium carrier concentrations

Compute the equilibrium carrier concentrations and the position of the Fermi level with respect to the conduction band edge for a uniformly doped Si region with N_D=1*10^16 cm^-3 and N_A = 1*10^17 cm^-3 at room temperature.

  Find the system-specific part of the response-output

Consider the first-order linear differential equation y(t) + 5 (dy(t) / dt) = x(t) Compute the zero-input response (general solution of the homogeneous equation) to find the system-specific part of the response

  Find the line-to-line voltage of the line at the sending end

A balanceed three-phase load of 15 MA with a lagging load factor of 0.85 is supplied by a 115KV subtransmission line. if the line impedance is 50+j100Ohm per phase, determine the following: (a) The line current of the load.

  Compute the probability that the system will fail

Calculate the probability that the system will fail in 3,000 hours. Supposing no failure of any component occurs in 5,000 hours of operation. What would be your revised estimate of failure rates of the components in your system?

  Determine the power factor for the combined load

A company has 100 metal halides (400W each with 1.2 ballast factor) and four motors (each with 50 hp capacity, 95% efficiency, 100% load factor, and 80% power factor). The power factor for the combined load

  What is the symbol rate and what is the bandwidth

What is the symbol rate and what is the bandwidth occupied by the 16-QAM signal? The link must maintain a BER no higher than 10^-6. What is the minimum CNR in the receiver to meet this requirement?

  Build a home security system circuit

Build a home security system circuit using this program. The system must include a door sensor,window sensor, smoke detector, water leak sensor, a motion detector.

Free Assignment Quote

Assured A++ Grade

Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!

All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd