A paper mill has installed three steam generators (boilers) to provide process steam and also to use some its waste products as an energy source. Since there is extra capacity, the mill has installed three 5-MW turbine generators to take advantage of the situation. Each generator is a 4160-V 6250-kVA 0.85-PF- lagging two-pole Y-connected synchronous generator with a synchronous reactance of 0.75Ω and an armature resistance of 0.04Ω. Generators 1 and 2 have a characteristic power-frequency slope sP of 2.5 MW/Hz, and generator 3 has a slope of 3 MW/Hz.
(a) If the no-load frequency of each of the three generators is adjusted to 61 Hz, how much power will the three machines be supplying when actual system frequency is 60 Hz?
(b) What is the maximum power the three generators can supply in this condition without the ratings of one of them being exceeded? At what frequency does this limit occur? How much power does each generator supply at that point?
(c) What would have to be done to get all three generators to supply their rated real and reactive powers at an overall operating frequency of 60 Hz?
(d) What would the internal generated voltages of the three generators be under this condition?
The paper includes Lithium ion battery technology with its advantages and disadvantages. The paper discusses about the Lithium air battery in which detailed reactions of Lithium with air including nonaqueous as well as aqueous are given.
Construction of different types of power transformer, significant energy savings
This document is shown a paper on Orthogonal frequency-division multiplexing with advantages, disadvantages and uses.
This assignment contains electronics engineering questions like State the commonly found components of a SCADA (Supervisory control and data acquisition) system. and decribe the function of the HMI in a SCADA system.
Prepare an Excel graph showing the individual components and summated resultant waveform of the odd harmonic series resulting in an approximate square wave.
Explain the function of the HMI in a SCADA system.
Design a 2-digit 24 second "shot-clock" countdown timer with pushbutton controller.
To understand dierent signal models To be able to model a discrete-time system and design simple signal processing algorithms.
Draw a relay construction diagram and briefly explain the operation of a relay.
Write a short technical report on Frequency Division Multiplexing
Briefly discuss the impact of electron energy, electron current and target on the Bremsstrahlung generated.
The schematic of the traffic light controller