Already have an account? Get multiple benefits of using own account!
Login in your account..!
Remember me
Don't have an account? Create your account in less than a minutes,
Forgot password? how can I recover my password now!
Enter right registered email to receive password!
An inverting op amp has Ri = 20 k Ohms, Rf = 500 k Ohms, and Req (resistor between + input terminal and ground) = 19 k Ohms. How much does the offset voltage increase if Req is replaced by a short circuit?
Design an RC low-pass filter with a cutoff frequency at 2kHz, using a capacitor of \(0.1\mu F\) A. Show a circuit diagram and your calculations in obtaining R B. Make as sketch of the absolute value of the input impedence
An LVDT is used in an accelerometer to measure seismic-mass displacement. The LvDT and signal-conditioning output is 0.31 mV/mm with a +/-2 cm maximum core displacement. The spring constant is 240 N/m, and the core mass is 0.05 kg.
The Dinorwig pumped storage hydroelectric facility in Northern Wales utilizes an abandoned slate quarry named Marchlyn Mawr as the upper reservoir. 600 meters below the Llyn-Peris lower reservoir can be found. The plant contains six 288MW generato..
A system is described by the differential equation ty'(t)-8y(t)=x(t). Classify the system as to linearity, time-invariance and stability. A system is described by the equation y(t)= \(\int_{t/3}^{-\infty}\)x( \(\lambda\)) d.
A Vs equals 1V source impedance 25ohms is connected by a switch to a 50-ohms lossless air transmission line 1 m long, terminated in a load of 30-ohms. At time t=0s, the switch is closed instantaneously to launch a step voltage down the line.
A firm leases land from you for 15 years to build a warehouse. As payment you will own the building after 15 years estimated to be worth $400k however you must pay taxes and maintenance of $15k per year.
Low doped silicon is used in partide detectors, in order to obtain a wide depletio region. Consider a pn junction with p-side doping Na = 5 X 1012 cm-3 and n side doping Nd = 1017 cm ".
A 30hp 3 phase 360v 60 Hz induction motor has total internal losses of 2,500 watts when operating at full load. What is the motor's full load efficiency
What are the rated full -load speeds of a 400HZ motor that may be connected for either two or four pole operation, assuming a full load slip of 4% for both cases
the power deliverd to a three phase Y-connected load is 3kw and the line-line voltage is 380v the load power factor is 0.85 lagging. determine the load current and impedance
From a high-level perspective, what is the major difference between the LM324 and the LF347. Which of the performance characteristics are significantly different because of this.
Determine the phase angle difference between the voltage and current, and whether the voltage leads or lags the current, if (a) V = 240/243 V rms and I = 3/9 A rms; (b) the power factor of the load is 0.55 lagging; (c) the power factor of the load..