High-tension line has an electrical resistance

Assignment Help Mechanical Engineering
Reference no: EM13946742

A 25-mm-diameter, high-tension line has an electrical resistance of 10-4  !1/m and is transmitting a current of 1000 A.

(a) If ambient air at 10°C and 5 m/s is in cross flow over the line, what is its surface temperature?

(b) If the line may be approximated as a solid copper rod, what is its centerline temperature?

(c) Generate a plot that depicts the variation of the surface temperature with air velocity for 1 10 m/s.

Reference no: EM13946742

Questions Cloud

What is the heat loss per unit length of pipe : What is the heat loss per unit length of pipe? Consider the effect of insulating the pipe with a rigid urethane foam (k = 0.026 W/m · K). Evaluate and plot the heat loss as a function of the thickness 8 of the insulation layer for 0 8 50 mm.
Is this a normal distribution : Create a frequency distribution table for your data. You can use Excel or Word. Calculate the standard deviation. Calculate the variance.
Key communication concepts you have gained : Determine the three (3) key communication concepts you have gained from this class. Explain the strengths and weaknesses of each. Propose how do you expect to use these concepts in your organization.
Calculate voltage v : Calculate voltage V0 (by hand). Show the work below.
High-tension line has an electrical resistance : A 25-mm-diameter, high-tension line has an electrical resistance of 10-4  !1/m and is transmitting a current of 1000 A. If ambient air at 10°C and 5 m/s is in cross flow over the line, what is its surface temperature?
Diameter experiencing cross flow of water : A computer code is being developed to analyze a tem- perature sensor of 12.5-mm diameter experiencing cross flow of water with a free stream temperature of 80°C and variable velocity.
Estimate the equilibrium temperature rise : Estimate the equilibrium temperature rise and estimate the time constant - write an expression for the estimated curve (theta as a function of time) using the numerical results obtained in parts a and b.
Determine the convection heat loss : Determine the convection heat loss from both the top and the bottom of a flat plate at Ts = 80°C with air in parallel flow at Too = 25°C, uoo = 3 m/s.
Temperature of wire and free stream temperature : For a fluid of arbitrary Prandtl number, develop an expression for its velocity in terms of the difference between the temperature of the wire and the free stream temperature of the fluid.

Reviews

Write a Review

Mechanical Engineering Questions & Answers

  Compute all internal angles of given the lengths

The bearing and distances of the traverse with stations 1,2,3 and 4 together with the radiations to the corners A,B,C and D of the building are shown below. The coordinates of station 1 are (5000E, 5OOON)

  Gas-turbine power plant operating on an ideal brayton cycle

A gas-turbine power plant operating on an ideal Brayton cycle has a pressure ratio of 6. The gas temperature is 350 K at the compressor inlet and 1450 K at the turbine inlet. Utilizing the air­ standard assumptions, determine (a) the gas temperature ..

  Constant-temperature compression to volumetric

A sealed piston-cylinder assembly contains 3 lbm of water. The water is initially at P1 = 40 psia and T1 = 300°F. The water undergoes two processes in series: Constant-temperature compression to Volumetric = 11.19 ft3, during which the water transfe..

  A room is heated as a result of solar radiation coming in

a room is heated by an iron that is left plugged in. is this a heat or work interaction? take the entire room including

  Determine the vapors final temperature

A well-insulated rigid closed tank contains a kg of saturated liquid-vapor water mixture at 1atm and quality 0.6842. The water is rapidly stirred by a 200Watt paddle source until it becomes saturated vapor.

  Dtermine a the compressor power in kw b the refrigerating

a vapor compression refrigeration cycle operates at a steady state with refrigerant 134a as the working fluid.

  The flow curve for austenitic stainless steel has the

the flow curve for austenitic stainless steel has the following parameters strength coefficient 1200 mpa and

  Refrigerant-134a enters the condenser of a residential heat

refrigerant-134a enters the condenser of a residential heat pump at 800 kpa and 35 degrees c at a rate of 0.018 kgs and

  The water level in the basement is now sinking about 04

you are trying to pump storm water out of your basement during a storm. the pump can extract 0.6 ls. the water level in

  Two mass are connected by a light inextensible cord

Two mass are connected by a light inextensible cord that passes over a homogeneous 4-kg cylinder having a diameter of 1200 mm. How long will it take the 7-kg mass to move from rest to a speed of 2 m/s^2

  Estimate the common logarithm of 10 using linear

estimate the common logarithm of 10 using linear interpolation.a interpolate between log80.9030900 and log121.0791812.b

  Where mechanical ventilation is required in welding standard

Discuss some of the circumstances where mechanical ventilation is required in the welding standards.