Already have an account? Get multiple benefits of using own account!
Login in your account..!
Remember me
Don't have an account? Create your account in less than a minutes,
Forgot password? how can I recover my password now!
Enter right registered email to receive password!
1. For the waveform shown below, obtain expressions for Fourier components for fundamental, 5th, 7th, and 11th elements, write out (using Taylor Series and Newton - Raphson method, you are not required to write the program) formulae for iterative evaluations of α1, α2 , α3 and α4 such that the resultant waveform gives fundamental at 0.85 Vd and eliminates 5th and 7th and 11th harmonics. 2.(a). In the single-phase interface for a bi-directional power flow, VS =240 V(rms) at 50 Hz and LS = 3.5 mH.. The switch-mode converter is PWM controlled in its linear range with . The converter is controlled such that iS is either in phase or out of phase with VS. Calculate the minimum value of Vd if the power flow through the converter is 5 kW (a) from the ac to the dc side and (b) from the dc to the ac side. 2.(b) For the converter above the DC side voltage is maintained to , Determine the phase angle between the inverter fundamental voltage,VC1, and grid side voltage such that the power delivered to the grid is 10 kW and the fundamental current leads VS by 150°. Calculate the reactive power to the grid and draw the phasor diagram. 3. A three-phase inverter is used for interfacing a PV power generator to the grid of 420 VLL (max) and 50 Hz. The per phase input filter inductor LS =2.0mH and the DC-bus voltage is controlled to 740 V. The converter is controlled such that the power angle is 7.44 degree leading and the real power supplied to the grid is 20 kW. The converter supplies reactive power to the grid. Calculate the converter voltage VC1, reactive power, the converter phase current and modulation index. 4. A three-phase inverter is used for interfacing a PV power generator to the grid of 415 VLL (rms) and 50 Hz. The input filter inductor LS =4.0mH and the DC -bus voltage is controlled to 800 V. The converter is controlled such that the phase angle between the fundamental phase current and system phase voltage is 165 degree and iDC is 25 A. Calculate the power and reactive power supplied to the grid, the converter voltage and modulation index and the power angle δ 5. A single phase-controlled converter is used to connect a renewable power source to the grid. The sinusoidal waveforms of the grid side voltage VS and current IS are shown in Fig. Q5 , where IS is chopped at phase angle 45° with respect to VS. Show that the rms value of the current IS is , where is the peak current. (The identity may be used.) The fundamental component of IS can be shown to have a magnitude of and 10º lagging phase shift with respect to VS,
A signal is quantized using PCM. The maximum signal to quantization noise ratio is 20dB. What is the number of uniform quantization levels needed
Consider a hollow cylinder with a length L along the z-axis and a radius R and a charge -Q, containing a wire also of length L and charge Q running co-axially to the cylinder at its center.
Project on LFC using tuned FOPID. I have considered a two area model. Need help regarding implementation of GA MATLAB code for a two area interconnected power system for LOAD FREQUENCY CONTROL.
The output becomes 1 and remains 1 thereafter when at leasttwo 0s and at least two 1s have occured as inputs, regardless ofthe order of occurrence. Assuming this is to be implemented as aMoore machine, draw a state diagram for the machine.
Suppose you are given the following task: "Find the smallest (in the signed sense) of a sequence of 100 8-bit values stored in sequential file register locations starting at file register 800." Write a short sequence of instructions to perform thi..
calculate the maximum (peak) percentage amplitude, phase and frequency error incurred in using the phasor approximations to narrowband FM for the sinusoidal case when a) β=0.20; b)β=0.50.
Three single phase transformers are used to form a three-phase transformer bank rated 13.8kV (delta)/120kV (wye). One side of the transformer bank is connected to a 120kV transmission line.
A sequential circuit receives decimal numbers encoded in BCD one digit (4 bits) at a time, starting with the least significant digit. The circuit outputs are the 10's complement of the input number, also encoded in BCD least significant digit first.
An equilateral glass prism w/ an index 1.42 has a beam of light incident on one face at an angle of θi to the normal. Determine the angle at which it emerges from an adjacent face of the prism.
Draw a block diagram for a datapath that contains: an 8-word, three-port register file; an ALU that accepts operands either from the datapath or from an external source; and a shifter that shifts the A operand from the register file before it goes..
If the above electrode is used tomeasure the pH of arterial blood in vivo, and if the subject isbreathing at 0.5Hz, in the steady state how much will the true amplitude of the oscillation in pH be attenuated at the output of the pH electrode
A 3-phase squirrel cage motor has maximum torque equal to twicefull load torque. r2 =0.3 ohms and x2 =3ohms. Determine the ratio of starting torque to full loadtorque, if it is started by (a) Direct on line starter(b) star delta starter
Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!
whatsapp: +1-415-670-9521
Phone: +1-415-670-9521
Email: [email protected]
All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd