Find voltage regulation for load at leading power factor

Assignment Help Electrical Engineering
Reference no: EM13228202

A 3 phase Y connected alternator is rated at 1600 KVA, 13500 V. The armature resistance and synchronous reactance are 1.5 ohms and 30 ohms respectively. Calculate the % voltage regulation for a load of 1280 KW at 0.8 leading power factor.

Reference no: EM13228202

Questions Cloud

Compute the number of joules of work accomplished : that during one such stroke the opposing pressure in the tire was 30.0lb/in2 above the normal atmospheric pressure of 14.7 lb/in2. Calculate the number of joules of work accomplished during each stroke (1 atm= 101.325 J)
Determine the range of the gain k for a system : A single-loop negative feedback system has the loop transfer equation: L(s) = Gc(s)G(s) = K(s + 2)2 / (s(s2 + 1)(s + 8)) a. Sketch the root locus for 0 K  infinity to indicate the significant features of the locus.
Improve supply chain performance : Describe at least one recommendation to improve supply chain performance and reasons why it might decrease costs while improving quality.
How can two weeks of sales enable a better order : How can two weeks of sales enable a better order ? What should the supplier be concerned about in deciding whether to accept this offer ?
Find voltage regulation for load at leading power factor : A 3 phase Y connected alternator is rated at 1600 KVA, 13500 V. The armature resistance and synchronous reactance are 1.5 ohms and 30 ohms respectively. Calculate the % voltage regulation for a load of 1280 KW at 0.8 leading power factor.
What is your counterargument to claim the original price : A buyer negotiating with a supplier suggests that as his order size increases, the supplier's price quote should decrease both because the fixed costs can be spread over a greater volume and because the learning curve should lower the variable cos..
Determine at rated load and unity power factor : In a 50 KVA, Y connected, 440 V, 3 phase, 50 Hz alternator, the effective armature resistance is 0.25 ohms per phase. Synchronous reactance is 3.2 ohms per phase. Determine at rated load and unity power factor,
What is probability distribution of equivalent construction : a road between fairbanks and nome, alaska, will have a most likely construction cost of $4 million per mile. doubling this cost is considered to have a probability of 30%, and cutting it by 25% is considered to have a probability of 10%.
What would be corresponding inventory levels : Provide the cycle stock, safety stock, in transit inventory and transport cost across all widgets to provide the desired in stock level and what would be corresponding inventory levels and total cost if products were shipped by air from Seattle to S..

Reviews

Write a Review

Electrical Engineering Questions & Answers

  Determine what is the transmission angle

A 5 GHz parallel polarized wave with amplitude 5 V/m is oblique incident from an air of (z 0. The angle of incidence is 53.13 deg. What is the transmission angle

  Calculate the value of vl developed across

Calculate the value of vL developed across a 300 H coil when the instantaneous rate of change in component current equals 500 mA/s.

  Calculate the signal to noise ratio of rms noise voltage

Calculate the signal to noise ratio given RMS Noise Voltage = 20mV and RMS Signal Voltage = 2.5V Calculate ETotalRMS given e21RMS = 5V and e22RMS = 7V

  Create a program using asmide

Create a program using AsmIDE, which utilizes the Fox 11 68HC11 microcontroller board: Speech timer where max time is 5 minutes Use the switches for:

  Design a critically damped series rlc circuit

Using the commonly available resistors, capacitors, and inductors, design a critically damped series RLC circuit (i.e., all three components are connected in series) with an undamped natural frequency of 20 krad/s.

  Explain saturated and unsaturated synchronous reactance

Saturated and unsaturated synchronous reactance, The following readings are taken from the results of an open- and a short-circuit test on a 9375-kVA three-phase Y-connected

  What are two fundamental advances

what are two fundamental advances in the circuit theory that were developed in the 19th century in response to the challenges of telegraphy?

  What is the range of the sensor voltage outputs initially

a. What is the range of the sensor voltage outputs initially and finally? b. What range of voltages would be expected to be measured 2 sec after the step change is applied?

  Determine the electric and potential in dielectric region

The upper and lower conducting plates of a large parallel-plate capacitor are separated by a distanced and maintained at potentials V0 and 0, respectively. A dielectric slab of dielectric constant 6.0

  Explain how an electric shock may occur

A process worker received an electric shock when she attempted to turn off a conveyer control. The toggle switch controlled the power to a variable speed drive. An examination found that dust had accumulated on the toggle switch. Moisture on the ..

  Determine the resistance of the rheostat in rotor circuit

A three phase, 25-hp, 440-V, 60-Hz, 1750 rpm, wound-rotor induction motor has the following equivalent circuit parameters:R1=0.20 ohms, X1=1.0 ohms, R2=0.15 ohms, X2=0.8 ohms, Xm=30 ohms The motor is connected to a three phase, 440-V, 60-Hz supply.

  Explain what parameter of the rectangular pulses

The location of the zeroes in the spectrum suddenly changes to 5 kHz, 10 kHz, 15 kHz.... What parameter of the rectangular pulses has changed and what is its new value?

Free Assignment Quote

Assured A++ Grade

Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!

All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd