Already have an account? Get multiple benefits of using own account!
Login in your account..!
Remember me
Don't have an account? Create your account in less than a minutes,
Forgot password? how can I recover my password now!
Enter right registered email to receive password!
A 3 phase Y connected alternator is rated at 1600 KVA, 13500 V. The armature resistance and synchronous reactance are 1.5 ohms and 30 ohms respectively. Calculate the % voltage regulation for a load of 1280 KW at 0.8 leading power factor.
A 5 GHz parallel polarized wave with amplitude 5 V/m is oblique incident from an air of (z 0. The angle of incidence is 53.13 deg. What is the transmission angle
Calculate the value of vL developed across a 300 H coil when the instantaneous rate of change in component current equals 500 mA/s.
Calculate the signal to noise ratio given RMS Noise Voltage = 20mV and RMS Signal Voltage = 2.5V Calculate ETotalRMS given e21RMS = 5V and e22RMS = 7V
Create a program using AsmIDE, which utilizes the Fox 11 68HC11 microcontroller board: Speech timer where max time is 5 minutes Use the switches for:
Using the commonly available resistors, capacitors, and inductors, design a critically damped series RLC circuit (i.e., all three components are connected in series) with an undamped natural frequency of 20 krad/s.
Saturated and unsaturated synchronous reactance, The following readings are taken from the results of an open- and a short-circuit test on a 9375-kVA three-phase Y-connected
what are two fundamental advances in the circuit theory that were developed in the 19th century in response to the challenges of telegraphy?
a. What is the range of the sensor voltage outputs initially and finally? b. What range of voltages would be expected to be measured 2 sec after the step change is applied?
The upper and lower conducting plates of a large parallel-plate capacitor are separated by a distanced and maintained at potentials V0 and 0, respectively. A dielectric slab of dielectric constant 6.0
A process worker received an electric shock when she attempted to turn off a conveyer control. The toggle switch controlled the power to a variable speed drive. An examination found that dust had accumulated on the toggle switch. Moisture on the ..
A three phase, 25-hp, 440-V, 60-Hz, 1750 rpm, wound-rotor induction motor has the following equivalent circuit parameters:R1=0.20 ohms, X1=1.0 ohms, R2=0.15 ohms, X2=0.8 ohms, Xm=30 ohms The motor is connected to a three phase, 440-V, 60-Hz supply.
The location of the zeroes in the spectrum suddenly changes to 5 kHz, 10 kHz, 15 kHz.... What parameter of the rectangular pulses has changed and what is its new value?
Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!
whatsapp: +1-415-670-9521
Phone: +1-415-670-9521
Email: [email protected]
All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd