Using energy concepts, find the internal self inductance per unitlength of a loss-less, conductive solid wire of radius ρ. You may assume that the current is uniformlydistributed through the cross-section of the wire.
Sketch the Bode plot (including the magnitude response and phase response) of a continuous- time LTI (Linear Time-Invariant) system described by the following transfer function: \(H(s) = 5(s + 2)/s^{2}(s + 10)\)
Frank D. Drake, an investigator in the SETI (Search for Extra-Terrestrial Intelligence) program, once said that the large radio telescope in Arecibo, Puerto Rico, can detect a signal which lays down only a picowatt of power over entire surface of ..
Study code acquisition in frequncy hopping spread spectrum communication systems.Describe and explain why it is necessary. Design and demonstrate a code acqusition method.
Assume that a Ga-As bond in GaAs has a bond energy of 1.0 eV. Calculate the energy needed to cleave GaAs in the (001) and (110) planes. Calculate the energy per area.
Given the ratings of a single-phase transformer - 3kVA 220V/110V 50 Hz, calculate the rated current for the primary winding and the rated current for the secondary winding. The currents in the transformer should not exceed these values during the ..
the rms voltage of a balanced 3 phase Y connected source is 110 volts at 60Hz. it is connected to a balanced Y Load by 3 distribution lines with an impedence on each line z=1+j2. the load impedence is z=19=j28 per phase.
Find the amount of work required for rearranging a uniformly distributed surface charge Q of radius a into a uniformly distributed volume charge of radius a how can i do this problem in 2 different ways.
Simplify the following circuit. Line A goes into an INVERTER, then into a NAND Gate, then into an OR Gate, then travels into another NOR Gate.
Flux weakening causes problems in both generators and motors. In generators, the effect of flux weakening is simply to reduce the voltage supplied by the generator for any given load. In motors, the effect can be more serious.
A 15hp (output power), 208V, three phase, six pole, y-connected induction motor has the following parameters: R1 = 0.1 ohm R'2= 0.1 ohm Xeq = 0.5 ohm A.) A fan type load is connected to the motor. The slip of the motor in this case is 2%.
A ideal transformer is rated at 4800/480 volt, at 75KVA. it is connected as a step down auto transformer. find the line and load voltages, turns ratio and total apparent, real and reactive power at full load and at 60% rated load at a power factor..
Two 16-bit numbers are present in memory location starting from 7000H onwards. Add these two numbers and store 17-bit result in memory location after data.