on an oscilloscope grid, the vertical axis is set to 1V/division, and the horizontal (time) axis is set to 1 ms/division.The postion of the CRT trace has been adjusted so that zero volt(ground) corresponds to the horizontal line in the center ofthe grid. if a signal v(t) = 2 V sin [2p (250Hz) t] is applied tothe scop input, sketch the waveform you would expect to see. (Assume t=0 corresponds to the left-most vertical line)
Assuming that the secondary is open-circuited and that the primary is connected to a 13.8-kV source, calculate the magnitude and phase angle (with respect to the high-voltage source) of the voltage at the secondary terminals.
A tree-phase, 60Hz, 5MVA synchronous generator has balanced line-to-line voltages of 8320V at its terminals. if the generator is supplying power to delta-connected, balanced load of 5MVA at a 0.8 lagging power factor
A liquid level system converts a 4-10 m level into a 4-20mA current. Design a three mode controller (PID im assuming) that outputs 0-5 volts with 50% PB, 0.03 min integration time, and 0.05 min derivative time. Fastest expected change time is 0.8 ..
In a step-down converter, consider all components to be ideal. Let v_0 = V_0 be held constant at 5 V by controlling the switch duty ratio D. Calculate the minimum inductance L required to keep the converter operation
Suppose that the cost of electrical energy is $0.12 per kilowatt hour and that your electric bill for 30 days is $60 (power usage only, not including other charges or taxes) Assume that the power delivered is constant over the entire 30 days.
A transmission line has a resistance of 0.001 pu , and 0.01 p.u reactance. Voltages at the both ends (p and q) of the transmission line are 1.0p.u each. Angle at bus "p" is 45o and the angle at bus " q" is 30o.
A balanceed three-phase load of 15 MA with a lagging load factor of 0.85 is supplied by a 115KV subtransmission line. if the line impedance is 50+j100Ohm per phase, determine the following: (a) The line current of the load
given a "black box" with two terminals. You play around with the box for awhileand make the following observations: (i) The output voltage from the box is sinusoidal. (ii) The peak magnitude of the open-circuit voltage at the terminals is 5 V.
A 500 line/mm diffraction grating is illuminated by light of wavelength 510 nm. How many bright fringes are seen on a 2.0 m wide screen located 2.0 m behind the grating
Draw a schematic for a home or office central air conditionning system.Label the elements. What would be the measured variable. The manipulated variable. A reasonable value for the set point. Name devices that might serve as elements.
inductor L and assume they have been connected for Consider a circuit consisting of a sinusoidal source V s (t) = cos (t) u (t) volts connected in series to a resistor R and an a very long time.
John's house is served electrically by a single phase transformer rated 15 kVA, 8160 / 220 V, 60 Hz. The leakage reactance of the transformer is 400 ohms referred to the high side. John wants to replicate an interesting EEE 360 experiment