An electrically-driven pump operating at steady state draws water from a pond at a pressure of 1 bar and a rate of 40 kg/s and delivers the water at a pressure of 4 bar. Evaluating electricity at 8 percents per kW/h estimate the hourly cost of running the pump
flow around a brindge pier is studied using a modeal at 110 scake. when the velocity in the model is 0.9 ms the
hot exhaust gases are used to heat water at 100kpa and 15 degree c to produce saturated water vapor at 200 degree c
Consider a power plant operating on an ideal Rankine cycle without feed water heating. Steam enters the turbine saturated at 1000F at the rate of 5 x10 lbm/H. The turbine exhausts to a surface condenser at 1 psia. The condenser has an overall heat tr..
A 1-m tank contains air at 10oC and 350 kPa is connected through a valve to another tank containing 3 kg of air at 35oC and 200 kPa. Now the valve is opened, and the entire system is allowed to reach thermal equilibrium with the surroundings, which i..
explore the n2nono2 equilibrium in ambient atmosphere p 1 atm t 25 oc after the oxides no and no2 have been produced
.water is the working fluid in a vapor power cycle. the pressure and temperature at the turbine inlet are 1600 psia and
Determine the force in members CJ of the truss
water in a pipeline flows with a velocity of 8fts. the pipeline supplies a tank with a level 30 ft above the pipe
How can you tell from a root locus if the settling time does not change over a range of gain values? What values of damping is associated when a pair of dominant poles Crosse the imaginary axis?
A liquid/vapor H2O mixture with 9.1 lb-m and a pressure of 1000 psia is heated at constant pressure until the temp is 600ºF. What is the final total enthalpy of the water, in BTUs?
The 'Tasty Morsels Chocolate Company' tracks the amount of chocolate found in its chocolate bars. The target is 26 grams and the upper and lower specifications are 29 and 23 grams, respectively. If their most recent X bar has a centerline of 25 and t..
Hot, moist outside air passes over a cooling coil, from which it exits in a saturated state at p=14.7lbf/in^2 and T=65F. The air is then mixed adiabatically with room air at p=14.7lbf/in^2, T=75F, phi=25%.