Draw the power triangle for each load and for combination

Assignment Help Chemical Engineering
Reference no: EM131154509

Two balanced, wye-connected, three-phase loads are in parallel across a balanced, three-phase 60- Hz, 208-V supply. The first load takes 12 kW at 0.6 power factor lagging, and the second load takes 15 kVA at 0.8 power factor lagging.

(a) Draw the power triangle for each load and for the combination.

(b) What is the total kVA supplied?

(c) Find the supply power factor, and specify whether lagging or leading.

(d) Compute the magnitude of the current drawn by each load and drawn from the supply.

(e) If wye-connected capacitors are placed in parallel with the two loads in order to improve the supply power factor, determine the value of capacitance in farads in each phase needed to bring the overall power factor to unity.

Reference no: EM131154509

Questions Cloud

How might april perceive these sounds differently : How might April perceive these sounds differently if she is listening to "Neutral Milk Hotel" in an outdoor concert arena vs. through the earbuds of an electronic device while sitting in her living room (please feel free to be creative with your a..
Determine the delta connected load impedances : Determine the delta connected load impedances if the system voltage is 440 V. With the information given, is it possible to find whether the load impedance is capacitive or inductive in nature?
Problem-focused coping and emotion-focused coping : What are the major differences between problem-focused coping and emotion-focused coping? Provide examples of each that would be applicable to a social or occupational setting
What professional organizations you might join : Write a 1- to 2-page paper discussing what professional organizations you might join, and websites you might visit, that would provide insight into a career that includes responsibility for IT governance and management.
Draw the power triangle for each load and for combination : If wye-connected capacitors are placed in parallel with the two loads in order to improve the supply power factor, determine the value of capacitance in farads in each phase needed to bring the overall power factor to unity.
How can you define a dual relationship to a layperson : How can you define a dual relationship to a layperson? What prohibitions does the APA Ethics Code place on psychologists regarding dual relationships? Do you agree with the prohibitions? Why or why not?
What would the syntax look like : Thinking about repetition loops and things we do more than once can help identify something you would store in an array. For instance, if we were to define an array named that contained temperatures for the past 19 days, what would the syntax loo..
Find the total real power supplied in kw : Two balanced, three-phase, wye-connected loads are in parallel across a balanced, three-phase supply. Load 1 draws 15 kVA at 0.8 power factor lagging, and load 2 draws 20 kVA at 0.6 power factor leading.
Have you had any experience with this knowledge-based : At any rate, user support isn't just looking after the least technological staff; increasingly, it's also providing for the power users, and those who would be power users. Have you had any experience with this knowledge-based tension between staf..

Reviews

Write a Review

Chemical Engineering Questions & Answers

  Determine the amounts of chlorine as ca(ocl)2 and naoh

A plating waste with a flow of 50 L/min contains 274 mg/L of NaCN. Determine the amounts of chlorine as Ca(OCl)2 and NaOH required to: (a) Oxidize the cyanide to cyanide; and (b) Oxidize the cyanide to CO2 and H2O.

  What is the temperature at the end of the heating

A sealed rigid tank of 1 m3 capacity contains 1.2 kg of water at 1 bar and 99.63 °C. To this tank we add heat until the pressure increases to 3 bar. What is the temperature at the end of the heating?

  Approximate percentages of the microconstituents

For parts (a), (c), (d), (f), and (h) of Problem 10.20, determine the approximate percentages of the microconstituents that form. (a) Rapidly cool to 250(C (480(F), hold for 103 s, then quench to room temperature.

  Describe the resting heart rates of the individuals

The fuzzy sets in Example Problem 10.26 have been calibrated so that a person with a resting heart rate of 95 beats per minute has a 75% degree of membership in the normal category and a 25% degree of membership in the tachycardia category. A rest..

  Descriptions of: indoor concrete maintenance chemicals

Descriptions of: indoor concrete maintenance chemicals used on indoor concrete flooring - high solids floor finish chemicals used on indoor concrete flooring

  The principle of lime soda process

What is the principle of lime Soda process? Give their functions with chemical reactions. 2. Write notes on reverse osmosis and ultra filtration.

  What is the new pressure in the tank

A sealed rigid tank is filled with 1 kg of steam at 200 °C and 10 bar. What is the volume of the tank? 0.5 kg of steam are removed from the tank. If the temperature remains at 200 °C, what is the new pressure in the tank?

  Calculate the efficiency at 3/4 load, 0.9 power factor

The efficiency of a 400-kVA, single-phase, 60-Hz transformer is 98.77% when delivering full-load current at 0.8 power factor, and 99.13% with half rated current at unity power factor.

  What materials of construction should be specified

What materials of construction should be specified

  Calculate the partial molar excess enthalpy

The table below gives the enthalpy of benzene(1)-heptane(2) solutions at 20 °C 1 bar as a function of the mol fraction of benzene. Calculate and plot the excess enthalpy at 20 °C, 1 bar.

  Pressure inside the vessel remains 38.6 kpa.identify liquid

A vessel holding some liquid is placed in a vacuum chamber that is constantly pumped. Gas leaks from the vessel into the vacuum through a small hole, radius 4.15 micro m, but the pressure inside the vessel remains 38.6 kPa. After a day mass of the..

  Determine the synchronous speed in revolutions

Determine the synchronous speed in revolutions per minute and the useful torque in new ton meters of a 200-hp, 60-Hz, six-pole synchronous motor operating at its rated full load (1 hp ≅ 746 W).