Consider a building whose annual air-conditioning load is estimated to be 120,000 kWh in an area where the unit cost of electricity is $.10/kWh. Two air conditioners are considered for the building.
Air conditioner "A" has a seasonal average COP of 3.2 and cost $5500.00 to purchase and install.
Air Conditioner "B" has a seasonal average COP of 5.0 and cost $7000.00 to purchase and install.
All else being equal, determine which air conditioner is a better buy.
1. a circular stainless steel rod is subjected to an axial load of 10 kips. what diameter must the rod be to have a
in an air-conditioning installation a flow rate of 1750 cfm of air at 50 degree ferenheit is required. a smooth sheet
A 1000 ft long metal duct is used to transport heated air from one side of a plant to another. The duct is 24in high by 36in wide. The heated air's temperature at the inlet of the duct is 170 F and the volumetric flow rate is 15,000 CFM. If the ambie..
calculate the energy for vacancy formation in al given that the equilibrium number of vacancies at room temperature 25
Liquid water at 25.0?C and 10.0 bar passes through a valve. The pressure drops to 1.00 bar. Calculate the temperature of the water in °C to three significant figures. You can assume that the water is an incompressible liquid with a density of 1000. k..
air at 800 kpa and 400oc enters a steady-flow nozzle with a low velocity and leaves at 100 kpa. if the air undergoes an
Determine the uniform tube wall surface temperature for these conditions. 0.050 kg/s. If a particular drying process requires approximately 1 kg/s of air at 75°C,
a house is maintained at 75degf in the winter by a heat pump. the house is losing heat at a rate of 60000 btuh through
The heat loss may be reduced by increasing the insulation thickness and/or reducing its emissivity. What is the effect of increasing the insulation thickness to 50 mm if B = 0.8? Of decreasing the emissivity to 0.2 if the insulation thickness is 2..
a 0.12-m3 rigid tank contains saturated refrigerant- 134a at 800 kpa. initially 25 percent of the volume is occupied by
a devise take 5 kgs of water at a pressure of 300 kpa and a temp of 180 degrees c. the water exists the devise at the
A mold has a downsprue of length = 6.0 in. The cross-sectional area at the bottom of the sprue is 0.45 in2. The sprue leads into a horizontal runner which feeds the mold cavity, whose volume = 75 in3. Determine (a) the velocity of the molten metal fl..