A capacitor is formed by two metal parallel plates with the dimensions 210 mm x 210 mm separated by the gap of 1.2 um (u=micro) filled with dielectric material with relative dielectric permittivity 3.8. What is the capacitance of this capacitor?
Design a 4-bit synchronous up/down counter using T flip-flops. The circuit has one input up' /down such that input 0 means count up and input 1 means count down. up' is "up" with a bar over it
Determine the gain K so that the phase margin is 45 degrees. For the gain K selected in part (a), determine the gain margin. Predict the bandwidth of the closed-loop system.
Consider the transformer to deliver its rated kilovoltamperes at 0.80 power factor lagging to a load on the low-voltage side with 240 V across the load. Find the highside terminal voltage.
A load has a 20 ohm resistor and a 4 Henry inductor connected in series. It is connected to a power source with v(t) = 100 cos(50t), connected in series to the load. What is the impedance of the load? Use phasor transform methods to obtain your an..
A farmer owns two barns; one north of a creek and the other south of the creek. The farmer has a Cabbage, a Goat, and a Wolf. The Farmer needs to put each item in a barn every night. If the Cabbage and Goat are in the same barn
(a) Determine the mean, variance, and standard deviation of X. (b) Determine the value for x such that P(-x
Find the input torque to the generator.If armature current and field current are kept constant, find the new value of the terminal voltage if the power factor is changed to 0.7 lagging.
A 3 phase Y connected alternator is rated at 1600 KVA, 13500 V. The armature resistance and synchronous reactance are 1.5 ohms and 30 ohms respectively. Calculate the % voltage regulation for a load of 1280 KW at 0.8 leading power factor.
Suppose you toss coins three times. Let X be the event that first of the three coin tosses results in "heads." Let Y be the event that you observe total of 2 "heads." Are X and Y independent events
Calculate the instantaneous power absorbed by the resistor, the instantaneous power absorbed by the capacitor, the real power absorbed by the resistor, the reactive power delivered by|the capacitor, the load power factor.
A sphere has a radius d and contains a non-uniform charge density of Pv=Po(1-r/d) C/m^3. (a). What is the enclosed Charge for r d (c). What is the electric field for r
A manufacturing plant has a 600V, 60Hz supply and the following loads: Lights: 24kW Electric furnace: 4.8 + j6.4%u03A9 with a current of 150A Motor loads, 160kW at 0.8 Power Factor, lagging.