Already have an account? Get multiple benefits of using own account!
Login in your account..!
Remember me
Don't have an account? Create your account in less than a minutes,
Forgot password? how can I recover my password now!
Enter right registered email to receive password!
Given the narrow audio bandwidth of a telephone transmission facility, a nominal SNR of 56DB and a distortion level of <0.2%. What is the theoretical maximum channel capacity (kbps) of traditional telephone lines? What is the actual maximum channel capacity?
The signal transmitted by a Base Station has a power of 1 mW at a distance of 1 m from the transmitter. Measurements have shown that the propagation exponent for the path loss is n=3 up to a distance of 1 km and n=4 beyond that.
A soccer player kicks a soccer ball of mass 0.45 kg that is initially at rest. The player's foot is in contact with the ball for 1.1 x 10-3 s, and the force of the kick is given by F(t) = [(6.1 x 105)t - (2.3 x 108)t2] N for 0 t 1.1 x 10-3s, where ..
Scenario/Summary: At least two of the following simulations must be attempted by the student. Verify Loop Analysis Method by MultiSim simulation Verify Superpposition Theorem Method by MultiSim simulation
A DSSS-CDMA signal has a chip sequence that is 1,000 chips in length. The sequence repeats every millisecond. Define DSSS-CDMA Chip Sequence
If these nominal non--ideal parameters are replaced, one at a time, by A = 50000, Ri = 1 M and R0 = 150 (each of which is twice as bad as the nominal values), which parameter has the largest impact on the output voltage
The voltages at the generators buses are maintained at a magnitude of 1.0pu. The generator one (G1) is connected to bus 1. The generator two (G2) is connected to bus 2. The bus angle at bus 2 is taken as reference and is 00.
Design a circuit that takes a sinusoidal input of varying frequency at 1V amplitude and produces an output amplitude of approximately 1V when the frequency is 1 Hz and approximately 0.5V when the frequency is 1,000Hz.
A 345-kV, 3-phase transmission line delivers 100 MVA, 0.866 lagging, to a DELTA connected load. Calculate the following: a.) The total real and reactive power delivered to the load. b.) The real and reactive power per phase.
How many different teams can be organized consisting of two men, two women, and two children? We have the following groups available for team assignments: six men, five women, and four children.
The following measurement were made on a two-port resistive circuit. With port 1 open, V2 =15V, V1 = 10 V, and I2 = 30 A. With port 1 short-circuited, V2 = 10 V, I2 =4 A, and I1 = -5 A. Find the parameters of the z-parameter two-port.
An additional variable power factor load is to be added to the factory. The new load will add 320kW to the factory. The power factor of the variable factor load is to be adjusted so that the overall power factor of the factory is 0.96 lagging.
Important information about Electrical Networks, Engine consumes 5kw of power and a reactive power of 2kvar at current of (3+j2) Amps.