Already have an account? Get multiple benefits of using own account!
Login in your account..!
Remember me
Don't have an account? Create your account in less than a minutes,
Forgot password? how can I recover my password now!
Enter right registered email to receive password!
a 4A current source is in parallel with a 30 ohme resistance, a 15 ohme resistance, and an unknown resistance, Rx. The current through the unknown resistance is 1A. Determine the value of Rx.
Locate and specify an appropriate sensor if it is to operate at 120 vac as an input to a PLC. Create the ladder diagram program to accomplish the specified control.
A mote draws an average of 200mA when "awake", 0.1mA when "sleeping", and 400mA (total) when "transmitting". Transmitting data takes 2ms, and sensor acquisition takes 1ms. If the maximum size battery available is 5000mAh
Assuming that we can determine the Thevenin equivalent resistance of our wall socket, why don't toaster, microwave oven,and TV manufactorer match each appliance's Thevenin equivalent resistance to this value
The data inputs I0 through I7 are wired as follows: I0 = I1 = 0, I2 = I6 = , I3 = I5 = I7 = 1; and I4 = D. (a) Determine the Boolean function that the MUX implements. (b) Implement the function using a 4×1 MUX with minimum extra logic gates.
A uniformly doped abrupt p-n junction (step junction) diode is fabricated. At room temperature 25% of the total space charge region (depletion region) is in the p region. The built in potential is also measured to be 0.710V.
Use a K-Map to design a circuit that has two operations. In mode 1, it outputs the value of the 3-bit input multiplied by 3. In mode 2, it outputs the number of 1's in the 3-bit input. Design a circuit that implements this function.
A p-n junction solar cell has Voc = .5 V and Jsc = 20 mA/cm2. A second cell of same area has Voc = .6V and Jsc = 16 mA/cm2. Assuming both cells obey ideal diode equation find the values of Voc and Jsc when connected in parallel and series
A three-phase transmission line having a reactance of 120 ohms per phase is connected to a wye-connected load whose resistance is 160 ohms per phase. If the supply volatge is 70kV line-to-line, calculate a) The line-to-neutral voltage per phase.
Ziegler-Nichols Open Loop Tuning Often, when working with a faster loop, many people will opt only for a PI control philosophy
Three 150 kVA, 480V/4000V,60 Hz single-phase transformers are to be installed on a 4000V, 3-phase line. The exciting current has a value of 0.02 pu. Calculate the line current when the transformers are operating at no-load.
A firm leases land from you for 15 years to build a warehouse. As payment you will own the building after 15 years estimated to be worth $400k however you must pay taxes and maintenance of $15k per year.
Two rectangular waveguides, one air filled with internal dimensions 2cm x 1cm and the other dielectric filled with internal dimensions 1cm x 0.5cm, have the same cut-off frequency for the dominant mode. what is The relative permittivity of the die..
Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!
whatsapp: +1-415-670-9521
Phone: +1-415-670-9521
Email: [email protected]
All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd