Already have an account? Get multiple benefits of using own account!
Login in your account..!
Remember me
Don't have an account? Create your account in less than a minutes,
Forgot password? how can I recover my password now!
Enter right registered email to receive password!
A three-phase, 60Hz, wye-connected synchronous generator has balanced line-to-line voltages of 480V at its terminals. The generator is supplying power to two balanced and delta connected, three-phase loads. the first load is made up of three 15<-30 Ohm impedances, while the secound load is made up of three 18<50 Ohm impedances. Determine the following:
(a) Total (i.e.,equivalent) load impedance per phase (i.e.,line to neutral).
(b) The line current Ia at the generator terminal. use a phase voltage of Va=277.1281<0 V (since 480/(3^root) V =277.1281 V).
(c) The total complex power provideed by the generator.
A standard silicon NPN BJT is to be used as an amplifier. The emitter voltage is biased at 4 volts, the base is biased at 5 volts, and the collector is biased at 10 volts. Will this circuit perform as desired? Why or why not.
The resistance per 304.8 m of copper wire uses in the extension cord of AWG 14,12,10,8 and 6 are 2.58,1.62, 1.02, 0.64 and 0.41 respectively. Assume a 2% allowable voltage drop. Show all working .
Three identical constant pitch thin helical coils (having a pitch 3mm, axial length 450mm and inner diameter 20mm) are positioned along a common axis. The axial distance between the first and the second is 55mm
a plane wave is obliquely incident onto the planar interface between mismatched, lossless, nonmagnetic, uniform media, yet undergoes no reflection. If incidence is at 54 degrees to the normal, at what angle to the normal does the transmitted wave ..
Suppose the information portion of a packet contains 10 bytes consisting of the 8- bit unsigned binary ASCII representation of string "Link Layer".
The charge entering the positive terminal of an element is q = 10 sin 4 piet mC while the voltage across the element (plus to minus) is v = 2 cos 4 pie t V. (a) Find the power delivered to the element at t = 0.3 s.
In a 50 KVA, Y connected, 440 V, 3 phase, 50 Hz alternator, the effective armature resistance is 0.25 ohms per phase. Synchronous reactance is 3.2 ohms per phase. Determine at rated load and unity power factor,
The tuning control is required to provide a uniform, linear change in frequency for a fixed rotation of the knob, e.g., 25 kHz per revolution at any operating frequency. You are considering three options for controlling the frequency
1.How is crude oil formed ?How is it found/discovered ? 2.How is natural gas formed? (Start with plankton) and include crude oil formation.
The sampled signal is passed through an ideal LPF which rejects all frequencies above 8 kHz and has a gain Ts. Les sR(t) be the output of the LPF. Sketch LT[sR(t)], in which FT[] denotes the Fourier Transform, in frequency domain.
Discuss different types of addressing modes of HCS12. What is a relative addressing mode What is the difference between a direct and an extended addressing mode Discuss how Registers X and Y are used in index addressing mode.
A 60-Hz, single-phase transmission line has a length of 80 miles. Its shunt conductance (G) is 3.4×10?11 S/mile, resistance (R) is 0.1 ?/mile, capacitance (C) is 16 pF/mile, and inductance (L) is 0.56 mH/mile 220 kV, 220 MVA with power factor
Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!
whatsapp: +1-415-670-9521
Phone: +1-415-670-9521
Email: [email protected]
All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd