Determine the synchronous reactance of the generator

Assignment Help Electrical Engineering
Reference no: EM13254358

The no-load voltage of a Y-connected synchronous generator is 3646V. When the generator delivers the rated load of 432kW at 0.8pf lagging, the terminal voltage is 3117.69V. If the armature winding resistance is negligible, determine the synchronous reactance of the generator. When the load is changed to 80 + j60 per phase, determine the terminal line to line voltage.

Reference no: EM13254358

Questions Cloud

Calculate the number of turns of the primary winding : A distribution transformer is used to supply a household. below. The load consists of eight 100-W bulbs, a 350-W TV, and a 15-kW kitchen range. If the secondary side of the transformer has 72 turns
Compare the firm profits and losses from currency hedging : Assess whether Markel Corporation can improve the performance of its currency hedging and increase its profits from it. Explain why or why not.
Eva was to render decorating services : Eva and Maria entered into a written contract pursuant to which Eva was to render decorating services for Maria for a total price of $75,000. After the services had been performed, a good faith dispute arose between Eva and Maria over whether all of ..
Explain the initial pressure of the reaction products : If the initial pressure of NH3(g) is 1.766 atm, calculate the % of NH3(g) left over after the reaction reaches equilibrium according to the balanced equation. The value of Kp at 600.0 °C is 455000.00. The initial pressure of the reaction products ..
Determine the synchronous reactance of the generator : The no-load voltage of a Y-connected synchronous generator is 3646V. When the generator delivers the rated load of 432kW at 0.8pf lagging, the terminal voltage is 3117.69V. If the armature winding resistance is negligible
What is the efficiency of the process : Given your output in part a, what is the efficiency of the process?
Determine the efficiency of the three-phase transformer : A 150kVA, 2080/208V, 60Hz, Y/Y connected, three-phase, step-down transformer consists of three identical single-phase transformers. Each transformer has the following parameter values: Rl = 0.45-ohm, Xl = 2.2-ohm , R2 = 4.5m-ohm
Find the electric force between the nucleus and electrons : A typical helium nucleus consists of two protons and two neutrons. What is the electric force between the nucleus and one of the electrons orbiting the nucleus
Define what is the solvent and the solute : Name a few solutions you come in contact with every day. What substances make up these solutions. What is the solvent and the solute

Reviews

Write a Review

Electrical Engineering Questions & Answers

  Find when the triggering angle is greater than 140 degrees

The average voltage across the load when the triggering angle is 140 degrees. Keep in mind that the conduction is incomplete when the triggering angle is greater than 140 degrees.

  Calculate the value of vl developed across

Calculate the value of vL developed across a 300 H coil when the instantaneous rate of change in component current equals 500 mA/s.

  Determine the capacitance of a parallel-plate capacitor

determine the capacitance of a parallel-plate capacitor having plates 14cm by 30cm separated by 0.01mm. The dielectric has (epsilon)(r)=15

  What is the pressure of the gas mixture

a sample of gas composed of 5.7 grams of carbon dioxide and 3.6 grams of neon in a container with volume 5.7L and temp 67 degrees Celsius. what is the pressure of the gas mixture

  What will be the appropriate values of quantizing level l

A binary channel with capacity 36 k bits/sec is available for PCM voic transmission. If signal is band limited to 3.2 kHz, then what will be the appropriate values of quantizing level L and the sampling frequency.

  What are differences between ms antennas and bs antennas

What are the main differences between MS antennas and BS antennas. List the antennas used at mobile stations and describe the construction and characteristics of one of them in detail.

  Calculate the line-lo-line voltage at sending end of feeder

The transformer is supplying a load of 325 MVA, with 0.93 power factor lagging at a voltage of 24 kV (line-to-line) on its low-voltage side. It is supplied from a feeder whose impedance is 0.11 + j2.2 ohms connected

  Compare the area-delay and power of the adders

Design a 16 bit adder using both the ripple carry and CLA methods. Use 4-bit CLA blocks for the carry-lookahead design. Use only two-input logic gates in your design. Simulate the design using LogiSim at the logic gate level.

  Determine the record speed in units of miles per hour

An unmanned X-43A scramjet test vehicle has achieved a maximum speed of Mach number 9.68 in a test flight over the Pacific Ocean. Mach number is defined as the speed of an object divided by the speed of sound.

  Find the min permissible sag for a span of 225 m

find the MIN permissible SAG for a span of 225 m using a copper conductor with 1.2 cm diameter and allowing a MAX conductor tension of 2200 kg/cm^2 . The horizontal wind pressure is 6 g/cm^2 and specific gravity of copper is 8.9

  Calculate equivalent series impedance and resistance

The nameplate on a 50-MVA, 60-Hz single-phase transformer indicates that it has a voltage rating of 8.0-kV: 78-kV. An open-circuit test is conducted from the low-voltage side, and the corresponding instrument readings are 8.0kV, 62.1A, and 206kW.

  What would be the new pressure of the gas in psig

When the piston is at its bottom dead center, the gas is initially at 10 psig, 65°F, and 10.5 in 3 . After compression and when the piston is at top dead center, the gas is 180°F and occupies 1.5 in 3 . What would be the new pressure of the gas in..

Free Assignment Quote

Assured A++ Grade

Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!

All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd