Already have an account? Get multiple benefits of using own account!
Login in your account..!
Remember me
Don't have an account? Create your account in less than a minutes,
Forgot password? how can I recover my password now!
Enter right registered email to receive password!
A base-station cellular communicationsystem utilizes arrays of f/2 dipoles as transmitting and receiving antennas. Assuming that each element is lossless and that the input power to each of the f/2 dipoles is 1 watt, determine at 1,900 MHz and a distance of 5kmthe maximum
(a) radiation intensity Specify also the units.
(b) radiation density (in watts/m^2) for each ?/2 dipole. This determines the safe level for human exposure to EM radiation.
Find the associated answers for: total circuit impeadance (Zt), Current source (RMS), Vc (RMS) w/ power factor, Vr (RMS), all in complex form/ rectangular form. Remember each question has to be done three times, one for each frequency.
Describe what precautions you will take in designing the analog front end of the instrument before you perform the sampling for DSProcesing. Justify your claims by using engineering arguments.
An n-channel JFET needs a NEGATIVE voltage applied to its GATE, relative to its SOURCE. If you have a single POSITIVE supply applied to the MASTER loop of a JFET, the mid point of the voltage divider will also be a positive voltage
Write an optimal sequence of control microinstruction
What type of cable is necessary for each connection: straight or crossover? You can assume that S1 and S2 do not have the ability to resolve crossovers (called Auto-MDIX).
Twenty voice signals are to be multiplexed and transmitted over twisted pair. What is the bandwidth required (in bps) if synchronous time division multiplexing is used
determine the power components of the combination of three individual loads specified as follows: (Load 1)250VA and pf = 0.5lagging; (Load 2) 180 W and pf=0.8 leading; (load 3) 300VA and 100Ar lagging
A 2.4KV, single-phase circuit suppllies a load of 250KW at a lagging power factor, and the load current is 160A. If it is necessary to improve the power factor, determine the following: (a)The uncorrected poer factor and reactive load.
A Si IMPATT diode is operated at 140 GHz with a dc bias of 15 V and an average biasing current 150 mA. (a) If the power conversion efficiency is 25% and the thermal resistance of the diode is 4OoCnV.
For a Wien-bridge oscillator Given R = 20Kohm and C = 10nF what is the frequency of oscillation Given a required frequency of oscillation of f = 3kHz and R = 5kohm, what should the value of C be
The input impedance of a JFET used in COMMON SOURCE configuration, is defined by two considerations: The JFET itself has a VERY HIGH INPUT IMPEDANCE, because the input is the GATE to SOURCE junction that is REVERSE biased
The One river Hydroelectric Project generated power for BPA along the Two River from the early 1800s until 1900, when it was decommissioned due to environmental issues. The maximum flow rate through the system was 25 m3/s, and the hydraulic head w..
Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!
whatsapp: +1-415-670-9521
Phone: +1-415-670-9521
Email: [email protected]
All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd