Already have an account? Get multiple benefits of using own account!
Login in your account..!
Remember me
Don't have an account? Create your account in less than a minutes,
Forgot password? how can I recover my password now!
Enter right registered email to receive password!
A composite load consists of 3 loads connected in parallel.Onedraws 100W at a power factor of .92 lagging, another takes 250W ata PF of .8 lagging, and the third requires 150W at a unity PF.The parallel load is supplied by a source Vs in series with a 10Ωresistor.The loads must all operate at 115Vrms.Determine a)the rms current through the source; b) the PF of the composite load.
Design a one bit block that can be cascaded together to generate the final signal. Assume that you are allowed to generate a different block to treat the signed bit. Provide design for the two blocks and the complete circuit.
Adding dopants to a sample of silicon is found to reduce the Hall coefficient by a factor of 10 and increase the conductivity by a factor of 5. What effect has this dopant addition had on the mean free path
If the temperature remains constant and the external currentlI increases, what happens to the size of the depletion region Why
The receiver uses a 10.7 MHz IF. For cost, power, weight and size reasons, it is desirable to use a single clock oscillator that will provide the frequency reference for the synthesizer, as well as providing the clock for data.
Suppose a data array has 30 numbers sorted from low to high already, where no two numbers are equal. We need to search whether any of the two randomly given key numbers, key1 and key2 is in the array. If yes, then find out the position index(es) f..
The total complex power delivered to the Y-connected 3-phase balanced load is 1152+j864 KVA. The line voltage at the terminal ofthe load is 4160V. a) Find the magnitude of the line current feeding the load.
4H-SiC is doped with 2 x 1017 cm-3 nitrogen donor atoms (Ec - Ed = 90meV). Use Nc = 4 x 1020 cm-3. a. Calculate the electron density at 300 K. b. Calculate the hole density at 300K after adding 2 x 1018 cm-3 aluminum acceptor atoms
A charged 100- picoFarad capacitor has initial voltage across it of 10 V. A 100 kohm resistor is suddenly connected across the capacitor (at t=0) to discharge it. What is the magnitude of the instantaneous current at 20 usec
a dsp system is given with the following specifications: design requirements: sampling rate 20,000 Hz Maximum allowable gain variation from 0 to 4,000 Hz = 2dB 40dB rejection at the frequency of 16000 Hz
A manufacturing plant has a 600V, 60Hz supply and the following loads: Lights: 24kW Electric furnace: 4.8 + j6.4%u03A9 with a current of 150A Motor loads, 160kW at 0.8 Power Factor, lagging.
calculate the load voltage in a transformer if supply voltage is 240 Volts. The resistance and inductance refered to the high side are as follows: Req is 29.12 ohms, Xjeq is j12.1 ohms, Rc is 1033 ohms and Xm is j1053 ohms.
The average power used by the resistor is what you pay to the electric company, but there is also reactive power for which you do not. The complex power supplied to the circuit is defined as: P = ½ V s I*
Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!
whatsapp: +1-415-670-9521
Phone: +1-415-670-9521
Email: [email protected]
All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd