Determine the mixture temperature leaving the mixing chamber

Assignment Help Mechanical Engineering
Reference no: EM13711529

In air-conditioning systems, streams of cold and warm air are mixed to get air with the right temperature. Consider a mixing chamber into which cold air enters at 8C and 100 kPa at a rate of 0.55 m^3 /s and warm air enters at 300C and 100 kPa. The ratio of mass flow rates of warm to cold air streams is 1.6. Using variable specific heats, determine the mixture temperature leaving the mixing chamber.

Reference no: EM13711529

Questions Cloud

Dertermine the final temperature of the water vapor : Water in a vertical piston cylinder is heated at constant pressure of 10 bar. It is initially at 179.9 0C and has a specific volume of 0.1 m3/kg and is heated to a final specific volume of 0.248 m3/kg. Changes in kinetic and potential energies are ze..
Determine the change in internal energy : 1 /2kg of a liquid-vapor water mixture in a rigid tank initially at 2 bar is heated by 120V heater for 5 minutes until it becomes a saturated vapor at 4 bar. Changes in kinetic and potential energies can be ignored.
Contribution of grain boundary strengthening in an alloy : Nan crystalline materials have grain sizes ranging from 0.01 to 0.1 microns. If the contribution of grain boundary strengthening in an alloy with grains of 0.1 microns is 20 MPa, what would you expect it to be if the grain size were reduced to 0.01 m..
Calculate the density and approximate modulus : A volume fraction f = 0.2 of silicon carbide (SiC) particles is combined with an aluminium matrix to make a metal matrix composite. The modulus of particle reinforced composites lies very close to the lower bound of Young's modulus for a composite.
Determine the mixture temperature leaving the mixing chamber : In air-conditioning systems, streams of cold and warm air are mixed to get air with the right temperature. Consider a mixing chamber into which cold air enters at 8C and 100 kPa at a rate of 0.55 m^3 /s and warm air enters at 300C and 100 kPa. The ra..
Throttled from saturated liquid state : Refrigerant-134a is throttled from saturated liquid state at 7 bar to a pressure of 1.4 bar. Determine the temperature drop during this process and the final specific volume.
Calculate the coefficient of performance of the heat pump : A heat pump supplies 40 kW of heat to maintain the inside of a house at 250C in cold winter months when the ambient temperature is 00C. Power required to operate the heat pump cycle is provided by a heat engine cycle which receives 10 kW of heat from..
What is the volume occupied by each gas at equilibrium : An insulated rigid container is separated into two parts using a partition that is free to move and the partition allows heat transfer without any energy storage by itself. Initially 2 kg of air at 5 bar and 350 K is contained on one side of the part..
The pressure is maintained constant in the cylinder : A piston-cylinder device contains 12 kg of saturated R-134a vapor at 3.2 bars. An electric source supplies 8 A current to a resistor within the cylinder for 4 minutes and there is heat transfer of 400 kJ to the system. During these energy interaction..

Reviews

Write a Review

Mechanical Engineering Questions & Answers

  Package design

Package Design Brief: Assume you are the packaging engineer for a large consumer products company. In this company, the Packaging Design Briefs are initiated by the marketing group and forwarded to the Package Engineering group.

  Mechanical engineering questions

Define dynamic viscosity, Determine the centroid, Pressure due to the height of liquid, Advantage of changing the liquid, Calculate the total moment about the hinge of the seal gate.

  Automatic control

DOF system and Find the differential equation describing the system

  Write a paper on boyle''s law

Write a paper on Boyle's law and describe Compression and Combustion stroke . Also explain Charles's law and illustrate SI engine and CI engine.

  Verify the law for parallelogram of forces

To Verify the law for parallelogram of forces, law for triangle of forces and law of polygon of forces. These laws are very useful to calculate unknown forces in very short time.

  Discharge pressure of the compressor

What is the discharge revised discharge pressure of the compressor.

  The Case for Global Accounting Standards

The role of IFRS in both developing and developed capital markets.

  Wind turbine

Wind turbines are becoming more and more common as a method of energy production, wind turbines by their very nature are dynamic and are subject to and create their own internal and external kinematics and kinetics.

  Advanced design methodologies

8 x product engineering and design review (week 2 – 12), ~3 pages per item which must contain a brief description of the product then delve into concepts such as materials selection, manufacturing methods, life cycle analysis, recyclability and overa..

  Design of absorption column and the cooler

Design of absorption column and the cooler. Process design of other units should be completed along with pipe sizes.

  Determine the maximum total bending moment

Determine maximum total bending moment (static plus dynamic) of the beam under steady-state conditions.

  Force of the water on the gate

Determine the magnitude of the horizontal and vertical components of the force of the water on the gate.

Free Assignment Quote

Assured A++ Grade

Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!

All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd