The following data were obtained or a 30-kva, 60 hz, 2400-240V transformer tested at 60hz.
Voltage (V), Current(A), Power(W)
O.C. Test 240V, 3.0 A, 230 W
S.C. Test 70V, 18.8 A, 1050 W
a). determine the primary voltage when 12.5 A at 240 V is taken from the low voltage side supplying a load of 0.8 p.f. lagging.
b). Compute the efficiency and regulation in part (a)
Isc of 3.3A under input power Pinput=1kW/m^2. Assuming diffusion dominated behavior and no parasitic resistance elements, what is the device conversion efficiency at the maximum power point
Derive the two-term including source match error correction formula. Note: For all of these derivations, you should identify your standards {match, short, open} but DO NOT assume anything about their values.
Calculate the inductive reactance per meter of a single-phase, 50-Hz, two-wire transmission line. Assume each conductor's radius is 9cm and the distance between the two conductors is 5m.
How many atoms are found inside a unit cell of a simple cubic, body-centered cubic, and faced-centered cubic crystal How far apart interms of lattice constant a are nearest neighbor atoms in each case, measured from center to center
Consider an industrial load that absorbs 40 kW of power with power factor 0.8 lagging from a 60-Hz transmission line of voltage VL= 240
Design a DC current source to meet the following specifications: - Current source value: 100 u-amps +/- 1% (over all possible load and supply voltage conditions). - Output resistance: >20 Mohms. - Available DC voltage sources are bipolar and range fr..
Write a c program that reads in ten integers from the user on a single line, and determines and prints the largest and the smallest integers in the group. If either the largest or smallest integer is a prime number, have your program indicate this..
Two resistances R1 and R2 are connected in series. We know that R1=60 ohms and that the voltage across R2 is three times the value of the voltage across R1. Determine the value of R2.
Draw the correct circuit to serve a 7.2kv single-phase load from a 2.4kv source. If the laod is 50kVa at pf=.8 lagging, compute the secondary and primary phasor currents. is this a step-up or step-down application
Determine the input current and the load current and voltage. Also, calculate the power absorbed at the load. Use the data from A above, but assume the load is an open circuit. Determine the input current and the load current and voltag..
A three-phase, four-pole, 50-hp, 480-V, 60-Hz, Y-connected induction motor has the following parameters per phase: r1 = 0.10 , x1 = 0.35 , r2' = 0.12 , x2' = 0.40 . It is known that the stator core losses amount to 1200 W and the rotational lo..
Given 01110110110100011001101111110000 base 2, determine in base: a) Decimal b)Hexadecimal