A cable TV receiver has an input impedance of 200 ohm The cable TV distribution system uses RG-6 cable. This cable has a characteristic impedance of 75 ohm Design an impedance matching stage to maximize the power transfer from the wire to the receiver.
A byte containing 01100011 is right shifted (right-most bit first) into an 8-bit shift register with an initial state of 00110110 (01100011=>00110110) What does the shift register contain after three clock pulses
For each one of the 3 frequency responses, H(f), in parts (a), (b), and (c) do the following: i. Obtain the system's impulse response, h(t). ii. Indicate if the system is BIBO stable or not, and state why. iii. Indicate if the system is causal or not..
1. What is the effect of increasing the quantization levels on the quantization error in a PCM signal 2. How can we increase the data rate in a digital signal
Consider two Si samples; one is p-type doped to 1018/cm3 acceptor atoms and the other one n-type doped to 1015/cm3 donor atoms at room temperature (300K). a. Draw the band diagram associated with p-type and n-type semiconductors, noting the various..
Two generators are connected in parallel to the same bus bar and each has an inductive reactance of 10% on rating. Generator 1 is rated 2,500 kVA and 2.4 kV, and generator 2 is rated 5,000 kVA and 2.4 kV.
Obtain polar plot using nyquist command. determine the stability of closed loop system based on nyquist criterion. design a compensator to meet the P.O. = 10%. Plot the before and after plot on the same nyquist plot.
An alarm is powered by 120 VAC, and the on/off state of the alarm is controlled by an EM relay. Design the interface between a computer output port and the EM relay. The dropout voltage is 3.5 V, and the coil current needs at least 100 mA.
1. Calculate the total (composite) load power factor, true power, reactive power and apparent power. 2. Also calculate the full-load current and the amount of capacitive KVAR needed to bring the overall power factor to .95 lagging.
The voltage across the load must remain between 4.7 and 5.0 V for all values of load current. Design a voltage-divider network to supply the load. You may assume that resistors of any value desired are available.
A 150MW alternator generates an open-circut line-t0-line voltage of 12kV at nomial DC excitiation. When the terminals are placed in short-circuit the resulting current per phase is 8000A. a) Calculate the approximate value of the synchronous reacta..
A body attached to earth ground by an electrical conductor is at zero electrical potential. A charge of 25 C is added to the body. What is the potential of the body now. Explain.
If the output of the function generator for a sinusoidal waveform is 6 voltage divisions peak to peak and the voltmeter reads 2.12V, find the volts/div scale that is being used. If the frequency is 1 KHz and the peaks are 5 horizontal divisions ap..