Design an embedded system to turn on an LED when it is dark and turn off of LED during the day time.
A Motorola 68000 microprocessor-based data acquisition system incorporates memory ( EPROMS and SRAMS), an Analog-to-Digital Converter (A/D), a Centronics Parallel Printer, and a very simple I/I Device made up of a single push-button switch.
Design a multi-function unit with 4 functions chosen using select inputs s1s0. The unit has two 2-bit inputs (A = a1,a0 and B = b1,b0) and 4-bit output (z3,z2,z1,z0). The unit performs A+B (s1s0 = 00), AB (s1s0 = 01), A2+B (s1s0 = 10)
Two DTEs are communicating via modems and RS-232C interfaces over a half duplex link. Data transmission is one directional with each message of length M. After a message is transmitted, the sender waits for a CTS message.
A three-phase, 60Hz, wye-connected synchronous generator has balanced line-to-line voltages of 480V at its terminals. The generator is supplying power to two balanced and delta connected, three-phase loads. the first load is made up
Design a Double Sideband Amplitude Modulation (DSBAM) modulator and demodulator system using the SystemView software. The modulating wave m(t) = Amcos(2pifmt) and the carrier wave c(t) = Accos(2?fct) have the following parameters
Use the fact that x = 2 and y = 0 at t = 0 to determine the appropriate value of the arbitrary constant in the solution set.
A 10m diameter cylindrical tank is emptied by a constant outflow of 1 m3 /min. A two position controller is used to open and close a fill valve with an open flow of 3 m3 /min. For level control the neutral zone is 1m and the setpoint is 10m.
Data Transfer/Manipulation Instructions a) If accA holds $16 and accB holds $2A, what memory locations will change value after executing the STD $637F instruction. Identify the new value in any changed memory locations.
Reduce the two functions given below and implement them using fewest 8x2 ROM's. Draw a neat labeled diagram showing interconnection between the ROM's address and data lines, and content of each ROM.
Locate and specify an appropriate sensor if it is to operate at 120 vac as an input to a PLC. Create the ladder diagram program to accomplish the specified control.
The input power to the geenrator is 100hp. When the generator is operating at rated values and unity power factor, the generator is 80% efficient. a.) Find the generator speed in rpm and rad/sec. b.) Find the mechanical torque supplied to the gener..
Assuming that the maximum depth of Kraken Mare is less than 400 meters, how much pressure in atmospheres must the submersible be designed to withstand Assumer the surface pressure on Titan is 17 kilopascals, the surface temperature is 94 kelvin