Design all floor to beam and beam to column connections

Assignment Help Civil Engineering
Reference no: EM132314096

Application of timber in Engineering Structures - Design Assignment

Assignment Details - This assignment covers the main design competencies required for undertaking a commercial timber building design project. To complete the assignment, students are expected to put considerable amount of work including research to find relevant information to complete the design successfully.

What is required?

You are required to undertake the detail structural design of a 40m x 24m office building (2 storey) located in Sydney (Wind Terrain Category 3). Details of the required building plan and elevation is given in the attached drawing. The structural importance of the building is classified as normal. The design brief will require you to prepare options for each design stage and make recommendation on the preferred option.

You must design the building to conform to AS/NZS 1170 for gravity and wind loads, to meet SLS and ULS criteria. Since the wind loads are more critical than seismic, you are not required to design for earthquake events.

The available material is generally classified as (i) Grade 11 pine LVL, either 45mm or 63 mm thick - sourced from Australia or New Zealand and (ii) 3, 5 or 7 layered CLT panel options are available from XLam New Zealand.

You may assume that the foundations and basement masonry walls / retaining walls will be designed by others. The structural system for the building is essentially post and beam and / or portal construction with appropriate lateral bracing. All other walls are non-load bearing and as such, you do not need to design the infill walls.

You must design each of the design alternatives/options and make decision on your final choice/recommendation before moving to the next step.

Flooring - 2 options required (both simply supported single span):

  • Floors must be designed to resist an imposed load of 3 kPa distributed loads, in conjunction with a 3.5 kN concentrated load.
  • Option 1 - a Timber composite floor spanning up to 8 m.
  • Option 2 - a CLT floor spanning up to 8 m.
  • All floor options must be designed for a deflection limitation of span / 300 for a short term SLS load of 0.7 Q.
  • Design suitable floor support beams (spanning between columns / portal frames) to support the main floor.
  • Provide specification / details for acoustic / fire separation to meet a 60 minutes FRL fire rating.

Framing - 2 options required:

  • Option 1 - floor beams, columns and bolted roof trusses. You only need to design the standard truss- do not worry about the corner ridges.
  • Option 2 - a gable portal frame (with floor beams as required) over the entire building. Whilst the architectural drawing gives guidance on the roof pitch, variation to it is acceptable as long as the roof height is not exceeded. You also have the flexibility to decide on the column / frame spacing.
  • Design suitable lateral bracing in both directions to resist horizontal wind loads.

Connections:

  • Design connections for both framing options, noting the portal connections must be moment resisting and the truss connections must be bolted.
  • Design all floor to beam and beam to column connections.

Submit a soft copy of the following -

A professional design report that includes:

  • An executive summary
  • Summary of all design assumptions, including loads
  • A summary table indicating the selected member sizes for each major structural element, including connections
  • Detailed calculations for all members and connection presented in an appendix

CAD drawings - Should be drawn to scale and show preliminary design details for the structural elements of floor, wall and roof framing, bracing and connections.

Specification Sheet - A specification sheet should accompany the drawings and present any specific design assumption that a builder would need to know in order to construct the building.

Note - Need only report for flooring part which is in assignment brief which attached. Need calculations all in excel sheets attached separately? Need calculation for two separate flooring options that is lvl and clt and choosing best among them design of suitable floor support beams and there calculations to support main floor vibration check and provide detail for acoustic and fire separation to meet 60 minutes of frl fire rating.

Attachment:- Assignment Files.rar

Reference no: EM132314096

Questions Cloud

Understanding of the term return on investment : As a project leader, demonstrate your understanding of the term Return on investment (ROI).
Purpose of monitoring the flexible workforce arrangement : Detail three methods that may be used for the purpose of monitoring the flexible workforce arrangement for ongoing suitability to work requirements.
Opportunity might project completion create : What business opportunity might project completion create?
Considering the contractual obligations and implications : A project risk plan has been put into place for Construction. A serious mishap occurs in the project build, based on assumptions
Design all floor to beam and beam to column connections : Details of the required building plan and elevation is given in the attached drawing. The structural importance of the building is classified as normal
When using the atom process to manage risks : When using the ATOM process to manage risks, why is it important to engage stakeholders in the risk assessment process
Project management options in terms of schedule : What project management options in terms of schedule, performance, and cost do you have if progress on a work site is stopped
What project management options in terms of schedule : What project management options in terms of schedule, performance, and cost do you have if progress on a work site is stopped due to a natural disaster
Differentiate projects from other functions : What are five characteristics which help differentiate projects from other functions carried out in the daily operations of the organization?

Reviews

len2314096

5/30/2019 4:51:26 AM

i need to make clear that i need only report for flooring part which is in assignment brief which i have attached i need calculations all in excel sheets attached separately i need calculation for two separate flooring options that is lvl and clt and choosing best among them design of suitable floor support beams and there calculations to support main floor vibration check and provide detail for acoustic and fire separation to meet 60 minutes of frl fire rating and when i get report i need all excel sheet separately attached thank you waiting for reply as early as possible and report without plagiarism waiting for your response.

Write a Review

Civil Engineering Questions & Answers

  Engineering ethics and ethical issue

what is the engineering ethics course where to write about any engineering ethical case and discuss the ethical issue?

  Engineering ethics and concept and cases

what is the engineering ethics case related to civil engineering with reference and discuss all the engineering ethics issues which covered the "Engineering etics concepte and cases?

  Transportation and management

In the construction management, there is a lot of procurement route that are necessary and suitable for the construction industry.

  Supporting Investment Promotion: ERNST & YOUNG

Ernst & young is currently providing support to various sectors. In this regards it was felt that if this report is able to document good practices currently being adopted or planned in ceramic sector.

  Personalized Cancer Therapy-A step forward

Cancer is the uncontrolled growth of abnormal cells in the body resulting in tumours that can be benign or malignant (cancerous cells). A proper treatment is necessary to fight with this serious disease.

  Discuss the different environmental companies

Discuss the different agencies, institutes, centers, different environmental companies that are active in UAE.

  Develop a simple urban constructed wetland design

Develop a simple urban constructed wetland design.

  Evaluate company performance in relation to GRI standards

Evaluate company performance in relation to GRI standards and comment on Stigler's theory.

  Water system design

Determine the corresponding error in the computed discharge

  Hydraulic behaviour in open channel

Describe how test flumes and associated equipment are used to assess and confirm hydraulic behaviour in open channel

  Write a paper on steel sustainability

Write a paper on steel sustainability.

  Writing case study about bridge collapse

Writing case study about bridge collapse