Design all floor to beam and beam to column connections

Assignment Help Civil Engineering
Reference no: EM132314096

Application of timber in Engineering Structures - Design Assignment

Assignment Details - This assignment covers the main design competencies required for undertaking a commercial timber building design project. To complete the assignment, students are expected to put considerable amount of work including research to find relevant information to complete the design successfully.

What is required?

You are required to undertake the detail structural design of a 40m x 24m office building (2 storey) located in Sydney (Wind Terrain Category 3). Details of the required building plan and elevation is given in the attached drawing. The structural importance of the building is classified as normal. The design brief will require you to prepare options for each design stage and make recommendation on the preferred option.

You must design the building to conform to AS/NZS 1170 for gravity and wind loads, to meet SLS and ULS criteria. Since the wind loads are more critical than seismic, you are not required to design for earthquake events.

The available material is generally classified as (i) Grade 11 pine LVL, either 45mm or 63 mm thick - sourced from Australia or New Zealand and (ii) 3, 5 or 7 layered CLT panel options are available from XLam New Zealand.

You may assume that the foundations and basement masonry walls / retaining walls will be designed by others. The structural system for the building is essentially post and beam and / or portal construction with appropriate lateral bracing. All other walls are non-load bearing and as such, you do not need to design the infill walls.

You must design each of the design alternatives/options and make decision on your final choice/recommendation before moving to the next step.

Flooring - 2 options required (both simply supported single span):

  • Floors must be designed to resist an imposed load of 3 kPa distributed loads, in conjunction with a 3.5 kN concentrated load.
  • Option 1 - a Timber composite floor spanning up to 8 m.
  • Option 2 - a CLT floor spanning up to 8 m.
  • All floor options must be designed for a deflection limitation of span / 300 for a short term SLS load of 0.7 Q.
  • Design suitable floor support beams (spanning between columns / portal frames) to support the main floor.
  • Provide specification / details for acoustic / fire separation to meet a 60 minutes FRL fire rating.

Framing - 2 options required:

  • Option 1 - floor beams, columns and bolted roof trusses. You only need to design the standard truss- do not worry about the corner ridges.
  • Option 2 - a gable portal frame (with floor beams as required) over the entire building. Whilst the architectural drawing gives guidance on the roof pitch, variation to it is acceptable as long as the roof height is not exceeded. You also have the flexibility to decide on the column / frame spacing.
  • Design suitable lateral bracing in both directions to resist horizontal wind loads.

Connections:

  • Design connections for both framing options, noting the portal connections must be moment resisting and the truss connections must be bolted.
  • Design all floor to beam and beam to column connections.

Submit a soft copy of the following -

A professional design report that includes:

  • An executive summary
  • Summary of all design assumptions, including loads
  • A summary table indicating the selected member sizes for each major structural element, including connections
  • Detailed calculations for all members and connection presented in an appendix

CAD drawings - Should be drawn to scale and show preliminary design details for the structural elements of floor, wall and roof framing, bracing and connections.

Specification Sheet - A specification sheet should accompany the drawings and present any specific design assumption that a builder would need to know in order to construct the building.

Note - Need only report for flooring part which is in assignment brief which attached. Need calculations all in excel sheets attached separately? Need calculation for two separate flooring options that is lvl and clt and choosing best among them design of suitable floor support beams and there calculations to support main floor vibration check and provide detail for acoustic and fire separation to meet 60 minutes of frl fire rating.

Attachment:- Assignment Files.rar

Reference no: EM132314096

Questions Cloud

Understanding of the term return on investment : As a project leader, demonstrate your understanding of the term Return on investment (ROI).
Purpose of monitoring the flexible workforce arrangement : Detail three methods that may be used for the purpose of monitoring the flexible workforce arrangement for ongoing suitability to work requirements.
Opportunity might project completion create : What business opportunity might project completion create?
Considering the contractual obligations and implications : A project risk plan has been put into place for Construction. A serious mishap occurs in the project build, based on assumptions
Design all floor to beam and beam to column connections : Details of the required building plan and elevation is given in the attached drawing. The structural importance of the building is classified as normal
When using the atom process to manage risks : When using the ATOM process to manage risks, why is it important to engage stakeholders in the risk assessment process
Project management options in terms of schedule : What project management options in terms of schedule, performance, and cost do you have if progress on a work site is stopped
What project management options in terms of schedule : What project management options in terms of schedule, performance, and cost do you have if progress on a work site is stopped due to a natural disaster
Differentiate projects from other functions : What are five characteristics which help differentiate projects from other functions carried out in the daily operations of the organization?

Reviews

len2314096

5/30/2019 4:51:26 AM

i need to make clear that i need only report for flooring part which is in assignment brief which i have attached i need calculations all in excel sheets attached separately i need calculation for two separate flooring options that is lvl and clt and choosing best among them design of suitable floor support beams and there calculations to support main floor vibration check and provide detail for acoustic and fire separation to meet 60 minutes of frl fire rating and when i get report i need all excel sheet separately attached thank you waiting for reply as early as possible and report without plagiarism waiting for your response.

Write a Review

Civil Engineering Questions & Answers

  Determine the head loss for the clean filter bed

The rapid sand filter being designed for Laramie has the characteristics show below. Determine the head loss for the clean filter bed in a stratified condition. Depth = 0.75 m

  Find what is the depreciation charges expect on the laptop

A laptop has a four year life span with an initial cost of $900 and $100 salvage value. According to the straight line method what is the depreciation charges you expect on the laptop

  Mass of water vapor diffuses through tube

If the water vapor is removed from the upper tank so that the concentration there remains nearly zero, what mass of water vapor diffuses through the tube each hour?

  Determine the seepage velocity-v through the sample

The cross-sectional area of the sample was 60 cm2 and its length was 150 mm. For 80 cm3/min steady-state flow rate, a total head difference of 8 cm was measured across two points separated by 10 cm along the axis of the sample.

  Explain plan for construction of a small child care center

describe how would you develop a subcontracting plan for the construction of a small child care center

  Which would be the strongest and highest bmelting point

explain how mechanical strength, melting temperature , and thermal exapntion are related at the atomic level. specifically, how do they relate to each other and the bonding energy between the atoms.

  Discuss the situation where tertiary treatment is required

Biological treatment processes for wastewater can be categorised as dispersed growth and attached growth systems. Discuss the advantages and disadvantages of attached growth systems over dispersed growth systems.

  How many tons of aggregate will be needed

Base course aggregate has a target dry density of 119.7 lb/cu ft in place. It will be laid down and compacted in a rectangular street repair area of 2000 ft x 48 ft x 6 in. The aggregate in the stockpile contains 3.1 percent moisture.

  Calculate the longitudinal and transverse stresses

Calculate the overall modulus of the composite, explaining your calculations and the assumptions you have made when it is loaded:

  Determine the new depth if the flow rate remains the same

During the following day the sun melts the ice cover. Determine the new depth if the flow rate remains the same and the surface roughness of the ice is essentially the same as that for the bottom and sides of the river.

  What is the 2-4-6-trichlorophenol concentration in ppm

A 500 L (132 gal) tank contains 255 mg/L 2,4,6-trichlorophenol dissolved in trichloroethylene (TCE). What is the 2,4,6-trichlorophenol concentration in ppm Assume the temperature of the system is 20 degrees C.

  Determine what is the saturation temperature of the system

The aluminum bar has an electrical coil imbedded in it, so that known amounts of heat can be transferred to it. Aluminum has a specific gravity of 2.70 and a specific internal energy given by the formulaU (kJ/kg)=0.94T(C).