Design a heat exchanger for the following dutyreduced crude

Assignment Help Chemical Engineering
Reference no: EM13374300

Design a Heat Exchanger for the Following Duty:

Reduced crude oil leaving a distillation unit with a flow rate of 3166.04 kL/d at 268 oC and is to be cooled to 243 oC by exchange with 62.8 kg/s pre-flashed crude oil coming from pre-flash unit at 206 oC. A pressure drop of 0.8 bar is permissible on both streams. Allowance should be made for fouling by including a fouling factor of 0.0003 (W/m2 oC)-1 on the reduced crude stream and 0.0002 (W/m2C)-1on the pre-flashed crude stream. Design and optimize a suitable shell-and-tube heat exchanger that can satisfy the above mentioned duty.

Hints:

  • Fix a tentative geometry and perform all standard calculations;
  • Verify the adequacy of your proposed design in terms of operating parameters; and
  • Modify the proposed design to make them compatible with the required allowances of parameters.

Appendix 1: Physical property data

Note that both pre-flashed crude and reduced crude are completely liquid over the range of temperatures and pressures experienced in the exchangers

1864_Design a Heat Exchanger for the Following Duty.png

Please include a brief comment on economic aspects of heat exchanger design including impact on overall heat transfer coefficient.

Please be sure to state any assumptions made in the calculations with justifiable reasons.

Reference no: EM13374300

Questions Cloud

Process principles assignment production of : process principles assignment production of formaldehydeworld formaldehyde production is estimated to be about 8
What are the couple rebuttals in the day that the world : what are the couple rebuttals in the day that the world almost came to an
Make this paper at least 1000 words and fix : make this paper at least 1000 words and fix nbspgrammarnothing is
Write a research paper onchildrens pastimes of today and : write a research paper onchildrens pastimes of today and yesterday.childrens pastimes of today and yesterday have
Design a heat exchanger for the following dutyreduced crude : design a heat exchanger for the following dutyreduced crude oil leaving a distillation unit with a flow rate of 3166.04
Write a research paper on the pros and cons of fraternities : write a research paper on the pros and cons of fraternities and sororities. it must be divided into four sections
In jane austens time marriage was the only way in which a : in jane austens time marriage was the only way in which a woman could escape poverty. but in emmas attempts to guide
Please discuss the following in the paper1 early years2 : please discuss the following in the paper1 early years2 influences and education3 in your own words explain what they
A literary analysis interpretation paper on things fall : a literary analysis interpretation paper on things fall apart by chinua achebe with two primary sources and two

Reviews

Write a Review

Chemical Engineering Questions & Answers

  The pressure of a sample of gas at a constant temperature

The pressure of a sample of gas at a constant temperature of 25 degrees C is increased from 1.0 atm to 1.2 atm. If the original volume was 3.8 liters, what will the new volume be?

  Question 1a outline the provisions of occupational safety

question 1a outline the provisions of occupational safety and health act 2005 with regard to substances hazardous to

  What is the nature of the process fluid

What is the nature of the process fluid and what are the objectives of the two sample points and in what way do the samples reaching the instruments differ?

  Calculate the values of the work interchange

Determine the values of the constants a and c and state the units and draw the path on a PV diagram also draw Path on the diagram and calculate the heat and work interchanges between the system and surroundings.

  Chemicals for indoor concrete flooring explanations

Important information about Chemicals for Indoor Concrete Flooring Explanations on high solids floor finish chemicals used on indoor concrete flooring

  Question 1with regard to the asymmetric heck reaction -

question 1with regard to the asymmetric heck reaction - from the rccent literature 2010-2014 please give three examples

  What is the drawdown

What is the drawdown at the perimeter of the well pumping 225 gpm when both wells are operating?

  Why a substance is being heated at a fast rate the

why a substance is being heated at a fast rate the temperature of decomposition will be the higher than the obtain at a

  Design a heat exchanger for the duty

Design a Heat Exchanger for the Following Duty: Reduced crude oil leaving a distillation unit with a flow rate of 3166.04 kL/d at 268 oC and is to be cooled to 243 oC by exchange with 62.8 kg/s pre-flashed crude oil coming from pre-flash unit at 206 ..

  Solve the initial value problem

Use Laplace transformation to solve the initial value problem

  Why a substance heated at a fast rate

Why a substance is being heated at a fast rate the temperature of decomposition

  Introduction to petroleum engineering

Present/display a research paper with the topic Introduction to Petroleum Engineering,giving preferences to the changes that are generated through the discipline in our world today.

Free Assignment Quote

Assured A++ Grade

Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!

All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd