1) Describe how you would implement it using an open-loop system2) Describe how you would implement it using a closed-loop system
3) What are the type(s) of sensors required in each case?4) Compare and contrast the potential problems that may arise in implementing the control system as an open-loop vs. a closed-loopsystem.5) Assume that one of the pumps uses a ¼ hp DC shunt motor with an input voltage of 115 VDC that pulls 1.6 A running at 1,500 rpm. The field resistance for the motor is 600 O and the armature resistance is 8.5 O. Find the constants Kemf and KT for this motor.The process to be controlled described earlier is a relatively simple process that can be implemented using straightforward methods. However, more complex processes require different types of control approaches.6) Describe Ratio Control and give an example of a situation in which you would use it.7) Describe Adaptive Control and give an example of a situation in which you would use it.8) Describe the similarities and differences between Cascade Control and Feedforward Control In most situations it is also desirable to send information from the process to be controlled, -in this case the 500 gallon tank- to a central station for processing and storage. This information can be transmitted and processed in different ways.9) Fieldbus is one of the methods used to transmit large amounts of process information. Describe the advantages and disadvantages ofusing Fieldbus.10) In the case of a problem in the communication process in general (not just using Fieldbus), describe how you would troubleshoot acommunications problem at the physical layer. Describe also the tools that you would use to troubleshoot the communications problem at thedata link layer.
The paper includes Lithium ion battery technology with its advantages and disadvantages. The paper discusses about the Lithium air battery in which detailed reactions of Lithium with air including nonaqueous as well as aqueous are given.
Construction of different types of power transformer, significant energy savings
This document is shown a paper on Orthogonal frequency-division multiplexing with advantages, disadvantages and uses.
This assignment contains electronics engineering questions like State the commonly found components of a SCADA (Supervisory control and data acquisition) system. and decribe the function of the HMI in a SCADA system.
Prepare an Excel graph showing the individual components and summated resultant waveform of the odd harmonic series resulting in an approximate square wave.
Explain the function of the HMI in a SCADA system.
Design a 2-digit 24 second "shot-clock" countdown timer with pushbutton controller.
To understand dierent signal models To be able to model a discrete-time system and design simple signal processing algorithms.
Draw a relay construction diagram and briefly explain the operation of a relay.
Write a short technical report on Frequency Division Multiplexing
Briefly discuss the impact of electron energy, electron current and target on the Bremsstrahlung generated.
The schematic of the traffic light controller