Create a calibration curve covering the expected blood

Assignment Help Chemistry
Reference no: EM131147423

When completing the Quality Control Sample and the five RSD samples.

How much of water/stock volume.

Could you also provide me with a brief explanation as to what the QC and RSD are and what they are used for so I can better understand.Analytical Methods -

Part A

Calibration Curve preparation (prior calculations required!)

Scenario

You have been asked by a senior analytical chemist to provide proof that your scientific analytical method for paracetamol is reliable and robust before they instruct you to perform an analysis on their behalf. To this end they have asked you to:

- Create a calibration curve covering the expected blood therapeutic to fatal levels of paracetamol, with an associated quality control and RSD samples as well.

You will have to find out some more information about this drug: find out the therapeutic and fatal blood drug concentrations of paracetamol, usually expressed in mg/L (or possibly μg/ml, which is the same) - note where a mass of drug is indicated this refers to a dose and not a blood drug concentration - do not confuse the two!

Instructions

For this lab session you ONLY have to prepare a calibration curve based on the information above, but you will have to do your calculations PRIOR to attending this session. Your samples will be racked and stacked in the trays provided and these will be run for you. It is essential that you have performed appropriate initial reading on the drug in question (to determine appropriate concentrations) and are careful with the preparation of your curve (pipetting skills, quality etc) as the appropriateness of the curve and its linearity will form the basis of this assessment.

You will need to construct a calibration curve covering this concentration range using a pure drug stock solution that has been prepared for you at the following concentration - paracetamol (2000mg/L) and will be available in the lab on arrival. To do so you will need to do your calculations PRIOR to attending this lab (time is limited and you will not have enough time to calculate and prepare your curve, so don't forget to bring your calculations with you!)

You will have to prepare your standards from this stock solution. It is likely that you will need to consider an intermediary stock solution in order to obtain an accurate calibration curve.

You should prepare FIVE standards you want to use for your calibration curve using GILSON pipettes only (Note you will NOT be using 10 ml volumetric flasks) - and don't forget about your blank!

Calculate what you intend the final concentration of each standard is to be and what volumes you need to take from the stock solution and water to dilute to achieve this concentration but bear in mind that you will prepare your calibration solutions directly into an autosampler vial (minimum volume 0.5ml, maximum capacity volume 1.8 ml) so you will have to think carefully about your volumes that you need to pipette and ensure they will fit in the vial!

Use this table to provide the following information:

Calibrant number

Concentration (mg/L)

Volume of stock (ml)

Calculation:

Blank

0

0

1

 

 

2

 

 

3

 

 

4

 

 

5

 

 

You will also need to include your full calculation of at least 1 concentration to illustrate that you understand the principles behind this calculation.

1) Using your notes, prepare your set of calibration standards that cover the appropriate concentration range using the apparatus provided - make sure you have labelled your glassware appropriately.

2) Make sure the vials have your name and your concentrations written on them. Rack these samples into the tray provided as well as documenting the appropriate details on the log sheet provided next to the tray.

3) Leave a copy of your calculations and table of concentrations with your name clearly printed on it.

Analytical Methods - Part B

QC & RSD Preparation

Quality Control:

Prepare 1 quality control (QC) sample in duplicate at a concentration of 50mg/L. You will have to calculate how to prepare this sample from the stock solution of 2000mg/L.

RSD:
Prepare 5 samples at a concentration of 100mg/L. You will have to calculate how to prepare these samples from the stock solution of 2000mg/L.

Rack these samples into the tray provided as well as documenting the appropriate details on the logsheet provided next to the tray.

Accuracy:

Take note, this QC has already been analysed and your results will be compared against this analysis. If your calculated analytical result deviates <3% from the previously analysed QC, then you will score 100% for this part of the assessment ie 10 marks out of 10. If however your calculated result indicates a 10% deviation then you will score 6 marks out of 10 for this part of the assignment and so on according to the accuracy of your data.

Precision:

The preparation of your 5 samples will be used to calculate the RSD. This calculation will measure how precise you are in repetition of a single sample concentration preparation. It also gives an indication of the performance of the HPLC system (which is known to be 0.5%). As with the accuracy, the RSD data will be compiled and assessed as indicated by the tables below:

Assessment marking:

The Quality Control data will automatically be inputted against your prepared calibration curve. Marks will be awarded according to closeness to target as indicated below:

Expected vs actual: criteria for error:


Error


Mark awarded

Mark awarded

<3%

10

Marks

20.1-30%

3

Marks

3.1-5%

8

Marks

30.1-40%

2

Marks

5.1-10%

6

Marks

40.1+%

1

Marks

10.1-20%

4

Marks

 

 

 

Quality Control = 10 marks available

The RSD data will automatically be calculated for you. Marks will be awarded on a sliding scale according to how precise (small % RSD) your data is as indicated below:

Expected RSD <1%:


Error


Mark awarded

Mark awarded

<0.5%

10

Marks

2.1+%

1

Marks

0.51-1%

8

Marks

 

 

 

1.1-1.5%

4

Marks

 

 

 

1.51-2%

2

Marks

 

 

 

RSD = 10 marks available

Reference no: EM131147423

Questions Cloud

Calculate return on equity using the dupont system : Assess management performance by calculating Economic Value Added (EVA). Evaluate the soundness of the company's financial policies (e.g. capital structure, debt, leverage, dividend policy, etc.) based on the material covered during class.
The speed of delivery processes for the introduction : The “speed of delivery” processes for the introduction of new products have recently witnessed great improvements. Briefly comment on the concepts that are used in such processes.
Evaluate both advocates position and the critics position : Select two subjects from the following list of topics and write a 1,050-word analysis:- Active monetary and fiscal policy, Increased government spending to fight recessions and Reducing federal government's discretionary powers.
Is increased always cohesiveness always desirable goal : How do various stragaties for improving surgical team communications reflect a desire to achieve cohesiveness? Is increased always cohesiveness always a desirable goal? Why or why not?
Create a calibration curve covering the expected blood : Create a calibration curve covering the expected blood therapeutic to fatal levels of paracetamol, with an associated quality control and RSD samples as well.
What do you think about the timing of douglass speech : What do you think about the timing of Douglass' speech? Do you think it was an appropriate speech to give on Independence Day? Why do you think Douglass thought it was an appropriate speech to give on Independence Day?
Explain surgical team as kind of functional group : Explain a surgical team as a kind of functional group. What features does it share with most functional groups? What features distinguish it from most fuctional groups?
Compare the roles of the medical director and the don : All nursing services in long-term care facilities are delivered by a nursing staff which is headed by a Director of Nursing (DON). Compare and contrast the roles of the medical director and the DON. Select the role which has the overall greater i..
Make contributions toward his health insurance : An employee got hurt on the job, was unable to work for a period of time, and received Workers’ Compensation benefits. His employer did not deduct the employee’s share of health insurance premiums from his Worker’s Compensation payment or otherwise n..

Reviews

Write a Review

Chemistry Questions & Answers

  A physician wrote a prescription for tylenol 325 mg5ml

a physician wrote a prescription for tylenol 325 mg5ml with codeine 10 mg5ml 5ml three times a day for 4 days as needed

  How to calculate the standard free energy change

A diamond is forever is one of the most successful advertising slogans of all time. But is it true? For the reaction shown below, calculate the standard free energy change at 298 K and determine whether or not a diamond is forever

  Explain what is the formula for the limiting reagent

What is the FORMULA for the limiting reagent. What amount of the excess reagent remains after the reaction is complete. grams

  State equation for ionization

What is the pH of a solution that is 0.30 M in Aniniline, C6H5NH2, and 0.15 M in Anilinium Chloride, C6H5NH3+ Cl-

  Compute the partial pressure of each gas

Consider a mixture is a 2 dm^3 flask at 27 degree C. For each of the following mixtures, calculate the partial pressure of each gas, the total pressure, and the compositon of the mixture in mole percent. (Hint: for mole percent take your answer fo..

  Define the empirical formula of the compound

0.4647g sample of a compound known to contain only carbon, hydrogen and oxygen was burned to yield 0.8635g of CO2 and 0.1767g of H2O. What is the empirical formula of the compound

  Explain what is the pressure in the container

Pure 2-methylpentane is held in a closed container at 150 degrees F. Both gas and liquid are present. What is the pressure in the container?

  Compute the mass of the solvent

Calculate the mass of the solvent (CCl4) in kg. Use the molality calculated in question 2 and the solvent mass calculated in question 3 to determine the number of moles of solute present in this solution.

  Describe and explain the possible effect of errors

Problem- Describe and explain the possible effect on your results of the following experimental errors or variations.

  Compute the number of liters of a 0.600 m k2cr2o7 solution

Specified the balanced reaction below for the oxidation of ethanol by potassium dichromate, compute the number of liters of a 0.600 M K2Cr2O7 solution required to generate 0.1665 moles of C2H4O2 from a solution containing excess ethanol and HCL.

  State ammonia used instead of hot water to separate lead ion

Question- 1. Could aqueous ammonia be used instead of hot water to separate lead ion from the mixed chloride precipitate? Explain.

  Explain what is the bromide in the original unknown sample

The resultant AgBr precipitate was removed and 1.0mL of 0.1000 M Fe3+ was added to the filtrate. Then 30.45mL of 0.2505 M KSCN was necessary to titrate the excess Ag+(aq). What is the w/w% bromide in the original unknown sample

Free Assignment Quote

Assured A++ Grade

Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!

All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd