A three-phase transformer is rated 500 MVA, 220 Y/22 Δ kV. The wye-equivalent short-circuit impedance, considered equal to the leakage reactance, measured on the low-voltage side is 0.1 Ω.
Compute the per-unit reactance of the transformer. In a system in which the base on the high-voltage side of the transformer is 100 MVA, 230 kV, what value of the per-unit reactance should be used to represent this transformer?
Identify appropriate materials used for its manufacture and the appropriate mechanical and thermal properties of these materials and discuss them in details.
Write a report on environmental companies
This assignment will be a deliverable oriented towards the grouping of project elements which organizes and defines the total scope of your project
Verify the bipolar junction transistor (BJT) voltage divider biased DC parameters through schematic theoretical analysis, simulated circuit analysis and constructed circuit analysis
Symmetrical Power system - modify the steps of solution without affecting the results
Identify which style of housing borrows from many housing designs of the past and present:-
We have a load resistance of 50Ω that we wish to supply with 5V. A 12.6-V voltage source and resistors of any value needed are available. Draw a suitable circuit consisting of them voltage source, the load, and one additional resistor. Specify the..
What are the compression ratio for S.I and C.I engines. Define Scavenging. What is meant by Pre-Ignition?. List out any two factors affecting the ignition lag. What is lean mixture.
Given a BJT unloaded amplifier shown in figure 1 below with β=100. Draw DC equivalent circuits of this unloaded amplifier. Draw the DC load line of the circuit. Determine the following dc values for the amplifier.
Complete the chart by adjusting the values of frequency and measuring Ic and Vc using the Agilent Multi-meter and then from these values calculating the value of Xc in the last column.
The Automatic Voltage Regulator (AVR) system of a generator is represented by the simplified block diagram shown, in which the sensor is modeled by a simple first-order transfer function
Water at 120oC with a quality of 25% has its temperature raised 20oC in a constant volume process. What is the new quality and pressure?