Compressor isentropic efficiency

Assignment Help Mechanical Engineering
Reference no: EM13949854

A vapor-compression refrigeration cycle with Refrigerant 134a as the working fluid operates with an evaporator temperature of 508F and a condenser pressure of 180 lbf/in.2 Saturated vapor enters the compressor. Refrigerant enters the condenser at 1408F and exits as saturated liquid. The cycle has a refrigeration capacity of 5 tons. Determine

(a) the refrigerant mass flow rate, in lb/min.

(b) the compressor isentropic efficiency.

(c) the compressor power, in horsepower.

(d) the coefficient of performance.

Plot each of the quantities calculated in parts (b) through (d) for compressor exit temperatures varying from 1308F to 1408F.

Reference no: EM13949854

Questions Cloud

Focus on international issues : Differences between managerial and financial accounting Product costing in manufacturing companies
Introduction of a regenerative heat exchanger : The Brayton refrigeration cycle is modified by the introduction of a regenerative heat exchanger. In the modified cycle, compressed air enters the regenerative heat exchanger at 350 K and is cooled to 320 K before entering the turbine. Determine, ..
Problem regarding the compressor pressure ratio : 1. Plot the quantities calculated in parts (a) through (c) of Problem 10.43 versus the compressor pressure ratio ranging from 3 to 6. Repeat for compressor and turbine isentropic efficiencies of 90%, 85%, and 80%.
Discuss and describe the traditional approach of a capital : Discuss and describe the traditional approach of a capital structure
Compressor isentropic efficiency : A vapor-compression refrigeration cycle with Refrigerant 134a as the working fluid operates with an evaporator temperature of 508F and a condenser pressure of 180 lbf/in.2 Saturated vapor enters the compressor. Refrigerant enters the condenser at ..
Destruction in the compressor and expansion valve : The isentropic compressor efficiency is 80%. Refrigerant exits the condenser as a saturated liquid at 160 lbf/in.2 The mass flow rate of the refrigerant is 0.15 lb/s. Kinetic and potential energy changes are negligible as are changes in pressure f..
Determining the coefficient of performance : There are no significant pressure drops in the flows through the evaporator and condenser. Determine the evaporator and condenser pressures, each in lbf/in.2, the mass flow rate of refrigerant, in lb/min, the compressor power input, in horsepower,..
Operation of a vapor-compression refrigeration cycle : Data for steady-state operation of a vapor-compression refrigeration cycle with propane as the working fluid are given in the table below. The states are numbered as in Fig. 10.3. The mass flow rate of refrigerant is 8.42 lb/min. Heat transfer fro..
Vapor-compression refrigeration system : A vapor-compression refrigeration system with a capacity of 10 tons has superheated Refrigerant 134a vapor entering the compressor at 158C, 4 bar, and exiting at 12 bar. The compression process can be modeled by py1.01 5 constant.

Reviews

Write a Review

Mechanical Engineering Questions & Answers

  Package design

Package Design Brief: Assume you are the packaging engineer for a large consumer products company. In this company, the Packaging Design Briefs are initiated by the marketing group and forwarded to the Package Engineering group.

  Mechanical engineering questions

Define dynamic viscosity, Determine the centroid, Pressure due to the height of liquid, Advantage of changing the liquid, Calculate the total moment about the hinge of the seal gate.

  Automatic control

DOF system and Find the differential equation describing the system

  Write a paper on boyle''s law

Write a paper on Boyle's law and describe Compression and Combustion stroke . Also explain Charles's law and illustrate SI engine and CI engine.

  Verify the law for parallelogram of forces

To Verify the law for parallelogram of forces, law for triangle of forces and law of polygon of forces. These laws are very useful to calculate unknown forces in very short time.

  Discharge pressure of the compressor

What is the discharge revised discharge pressure of the compressor.

  The Case for Global Accounting Standards

The role of IFRS in both developing and developed capital markets.

  Wind turbine

Wind turbines are becoming more and more common as a method of energy production, wind turbines by their very nature are dynamic and are subject to and create their own internal and external kinematics and kinetics.

  Advanced design methodologies

8 x product engineering and design review (week 2 – 12), ~3 pages per item which must contain a brief description of the product then delve into concepts such as materials selection, manufacturing methods, life cycle analysis, recyclability and overa..

  Design of absorption column and the cooler

Design of absorption column and the cooler. Process design of other units should be completed along with pipe sizes.

  Determine the maximum total bending moment

Determine maximum total bending moment (static plus dynamic) of the beam under steady-state conditions.

  Force of the water on the gate

Determine the magnitude of the horizontal and vertical components of the force of the water on the gate.

Free Assignment Quote

Assured A++ Grade

Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!

All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd