Already have an account? Get multiple benefits of using own account!
Login in your account..!
Remember me
Don't have an account? Create your account in less than a minutes,
Forgot password? how can I recover my password now!
Enter right registered email to receive password!
A 60-Hz, single-phase transmission line has a length of 80 miles. Its shunt conductance (G) is 3.4A1011 S/mile, resistance (R) is 0.1 OHMS/mile, capacitance (C) is 16 pF/mile, and inductance (L) is 0.56 mH/mile.
If 220 kV, 220 MVA with power factor 0.8 lagging is determined to be at the receiving end, calculate the voltage and the current at the transmitting end. Please inpuit in polar notation.
Assume that an additional inductance can be inserted in series with the load. Also assume that the converter has no freewheeling diodes. Calculate the added inductance that leads to a conduction period of 180 degrees when alpha = 30 degrees.
For the given circuit, determine the function of it I.e. is it OR gate? Or AND gate,.. Show all your answer, also draw the symbol and truth table of it.
The waveform output by the signal generator in part (b) is changed so that the rectangular pulses have the same width but no longer are periodic. They occur at random intervals of time. Explain in words how the display on the spectrum screen would..
transfer function: T(s)=1/(0.1s+1) with all initail conditions at 0 a) if the input is 1.5sin(2t)*u(t) find the steady state value of the output b) after the input is applied, approximately how long will it take for the steady state value you found i..
1- Draw a circuit whose output goes to + V sat . When the input signal is below -4V. the output should be -V sat, when the input is above - 4V 2- Design a - 90 phase shift circuit at 1590 Hz , Then for your design calculate 0 at 15 Hz, & 15 KHz
Determine the current drawn from a three-phase 440 V line by a three-phase 15-hp motor operating at full load, 90% efficiency, and 80% power-factor lagging. Find the values of P and Q drawn from the line. (Hint: 1hp = 746W)
The voltage across the load must remain between 4.7 and 5.0 V for all values of load current. Design a voltage-divider network to supply the load. You may assume that resistors of any value desired are available.
A) If 220kV, 220 MVA with power factor 0.8 lagging is determined to be at the receiving end, calculate the voltage at the transmitting end. B) If 220kV, 220 MVA with power factor 0.8 lagging is determined to be at the receiving end
The voltage on bus 1 is 1.0 per unit (pu) at 30 degrees; the voltage on bus 2 is 0.95 per unit at 5 degrees. The reactance connecting bus 1 to bus 2 is 0.5 per unit Ohms, and the resistance is negligible. a)How much real power (pu) is flowing from ..
Analysing spectrum anlyser output, A spectrum analyzer is connected to an unknown signal. The spectrum analyzer displays the power level of signals in dBm vertically and frequency horizontally. The spectrum of the unknown signal creates the follow..
If I have a resistor that is 10 Ohms and has a voltage drop of 4.2 V, how much current is flowing through the resistor?
Explain the operation of sequential logic devices and evaluate the output waveform in relation to the clock for QA, QB and QC in the subsequent circuit and show the binary sequence represented by these waveforms
Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!
whatsapp: +1-415-670-9521
Phone: +1-415-670-9521
Email: [email protected]
All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd