A 1,000 kVA, 3,200V, single phase 60Hz, 24 pole alternator/generator has an stator winding re-sistance of 0.1 ohm from line-to-neutral. The rotor is not a permanent magnet but a separately pow-ered electromagnet (field windings) that takes 100 A at 120 V. The power to run the filed is consid-ered a loss. The friction losses, including windage, are 15 kW. The core losses are 20 kW. a) Determine the output (line ) current based on kVA and ouput voltage. b) Calculate the total I2R resistance loss. c) Calculate the efficiency. (93.3 % answer) (Generator input = output + losses.
What would be the initial value of v c (t) when switch is closed and determine the time constants in both cases (switch is open, switch is closed).
Assume the z0 is in the far field and derive an expression for the strength to return as a function of angle. Make approximations where appropriate and do not forget the sidelobes.
The factorial of a nonnegative integer n is written n! (pronounced "n factorial") and is defined as follows: n!= n(n-1)(n-2)(n-3)....1 (for values of n greater than or equal to 1) and n!= 1 (for n=0) for example 5! = 5x4x3x2x1,
Calculate the approximate quantization S/N ratio in the baseband audio signal at the receiver output (after the DAC and LPF).
A 415V to 11 kV transformer has a rating of 200 kVA. The winding resistance and leakage reactance when referred to the primary are 0.014 and 0.057 ohms respectively.
2) Draw the logic circuit for each of the following. For each gate, determine EVEN or ODD parity and find the output for the given input data: a) 4-input XOR, input data=1001 b) 5-input XOR, input data-10010 c) 6-input XOR, input data=101001 d) 7-..
The tuning capacitor of a Wien bridge oscillator is 100 pF and the frequency is 5 kHz. To what value of capacitance pF should the capacitor be changed to if the frequency is to be changed to 2 kHz
A class C amplifier severely distorts the signal. How can we use a resonant tuned filter to get the desired signal at the output What type of transistor (BJT or FET) would you like to use at the front end (first amplifier) of a receiver
Three loads are connected in parallel across a single-phase source voltage of 240 V (RMS). Load 1 absorbs 12 kW and 6.667 kVAR; Load 2 absorbs 4 kVA at 0.96PF leading; Load 3 absorbs 15 kW at unity power factor.
A 150 MVA, 24 kV, 123% three-phase synchronous generator carries the rated load at a power factor 0.83 (lagging). Calculate the necessary excitation voltage and input complex power.
A tooling designer is designing a jig that will insert pins into the flip-up handles of a coffeemaker. The bin to hold the pins should hold enough pins for 3 hours' work before reloading. The engineering estimate for the rate of inserting the pins..
If the battery is replaced with a 6 Volt battery it was experimentally determine that the no load speed is reduced to 120 rpm. For this situation, determine a new equation for angular velocity,(in rad/sec) versus Torque (in Nm).
Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!
whatsapp: +1-415-670-9521
Phone: +1-415-670-9521
Email: [email protected]
All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd