A 3-phase, 3.3 kV, 50 Hz, 10-pole, star connected induction motor has a no-load magnetizing current of 45 A and a core-loss of 35 kW. The stator and referred rotor standstill leakage impedances are respectively (0.2 + j 1.8) and (0.45 + j 1.8) Ω/phase. The motor is supplied from 3.3-kV mains through a line of reac tance 0.5 W/phase. Use approximate circuit model.
(a) The motor is running at 0.03 slip. Estimate the gross torque, stator current and power factor. Assume voltage at motor terminals to be 3.3 kV.
(b) Calculate the starting torque and current when the motor is switched on direct to line with voltage at far end of the line being 3.3 kV.
Calculate this transformer's voltage regulation under the same conditions, using the per-unit system.
a fuse must be selected for a certain application. you may choosefrom fuses rated to "blow" when the current exceeds 1.5A, 3A, 4.5A,OR 5A. if the supply voltage is 110 V and the maximum allowable power dissipation is 500W, which fuse should be cho..
A MOD 12 and a MOD 10 counter are cascaded. The input clock frequency is 60 MHz. Determine the counter output frequency
Calculate the sag from the taller of the two supports which must be allowed so that the factor of safety shall be 5.
The average operator of a certain company performs at 100% (avenge path) and the tinge of performance is from about 60% to 140%, and the distribution is assumed to be oormaL Determine the station speed of the company's assembly line assuming that ..
A processor has a 32 MB cache and a 64 bit data bus. What is the minimum width of the address bus needed to access the entire cache
An electric heater is connected to a constant 240-V source and absorbs 1000 W. Subsequently, this heater is connected to a constant 210-V source. (a) What is the resistance of the heater
Calculate the magnitude of the phase voltage-Calculate the magnitude and phase of all line currents-Calculate the magnitude and phase of the neutral current
Calculate the current through a 1 mF capacitor in response to a voltage v if across its terminals, if v equals (a)30te-tV (b) 4e-5tsin100t V
Can protons every flow through current? Even though in the overwhelming majority of cases the current flowing through a material is dominated by the movement of electrons"
Design a circuit that has, as input, a transmit clock and an NRZ serial data signal (as in Figure 8.33 on page 354), and that generates a Manchester encoded serial data signal as output.
pressure limits of 10 kPa and 8 MPa, with reheat occurring at 4 MPa. The temperature of steam at the inlets of both turbines is 500°C, and the enthalpy of steam is 3185 kJ/kg at the exit of the high-pressure turbine
Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!
whatsapp: +1-415-670-9521
Phone: +1-415-670-9521
Email: [email protected]
All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd