Question 1. A road 300 m long is required to be illuminated by providing 40W fluorescent lamps. The width of the road is 4m. Design a street lighting scheme for obtaining minimum level of illumination of 0.6 lux assuming a mounting height of 9m and a 0.5 coefficient of utilization. (In designing you have to determine the distance between the poles and find out the number of poles required for the given distance.)
Question 2. A light assembly shop, 15m long, 9m wide and 3m up to trusses, is to be illuminated to a level of 200 lux. The utilization and maintenance factors are respectively 0.9 and 0.8. Make a scale drawing of the plan of the shop and set out the required lighting points, assuming the use of tungsten lamps and dispersive metallic reflectors. You may assume a lamp efficiency of 13 lm/W, and spacing height ratio of unity.
Question 3. A room measures 10mX20m and illuminated by 10 lamps of 700W each. It is illuminated semi-directly and the luminous efficiency of each lamp is 14lm/w. Allowing a depreciation factor of 1.7, determine the illumination of the working plane and guess the type of building considering the installation is correct.
Question 4. Given a 50m X 20m drawing room. It is required to illuminate semi-directly by 18W fluorescent lamps having an efficiency of 42 lm/W. Assuming a suitable space height ratio for new installation, estimate the no., rating and disposition of lamps if they to be mounted at 2.5m above the working bench.
Question 5. A hall 30m X 15m height is to be provided with a general illumination of 120lm/m2 Taking a coefficient of utilization of 0.5, depreciation factor 1.4 and appropriate space-height ratio, determine the no. of fluorescent tubes required, their spacing, mounting height and total wattage. Take luminous efficiency of fluorescent tubes as 40lm/W for 80 watt tube.
Question 6. A hall 15m by 20m is to be illuminated to a level of 70 lux. Luminaries having an efficiency of 12lm/w and spacing-height ratio 1.2 are to be suspended 4m above the flour. Estimate the no. of luminaries required and the power of each luminary. Assume a utilization factor of 0.5 and maintenance factor of 0.8. Also lay out the position of the luminaries.
Question 7. A room 7m by 10m is to be used as a general office and must be provided with illumination to a level of 4001x. 150w luminaries are to be installed giving a utilization factor of 0.5 and requiring a maintenance factor of 0.8. Assuming that the efficiency of luminaries is 13lm/w, calculate the no. of luminaries required.
Question 8. A road 300 m long is required to be illuminated by providing 40W fluorescent lamps.
The width of the road is 4m. Design a street lighting scheme for obtaining minimum level of illumination of 0.6 lux assuming a mounting height of 9m and a 0.5 coefficient of utilization.
(In designing you have to determine the distance between the poles and find out the number of poles required for the given distance.)
What are these distribution channels
: What are these distribution channels and how do they impact the sales of an enterprise.
|
Prepare journal entry to record transfer of finished goods
: Prepare the journal entry to record the transfer of finished goods from the Blending Department to the Bottling Department and post to the appropriate T-accounts prepared in requirement 2 above.
|
Class registration web form
: A class registration web form requires that students enter their current year. The entry options are numbers from 1 to 4 that represent the following: freshmen=1, sophomores=2, juniors=3, and seniors=4.
|
Who in the organization is best suited to staff the eoc
: Why would an organization want to set up an EOC when one already exists at the local or regional governmental level?Why is the physical setup of the EOC facility so important?How does the EOC communicate with other levels of the response and manageme..
|
Calculate the no of luminaries required
: Determine the distance between the poles and find out the number of poles required for the given distance - determine the illumination of the working plane and guess the type of building considering the installation is correct.
|
What has the performer intended
: In conclusion, what did you learn about yourself and theatre as a result of viewing this performance and completing this assignment? How can you apply and compare what you learned to your own major or field of study?
|
Database in unstructured data format
: What querying language would one use to query a database in unstructured data format?
|
What are the risks of determining a selling price
: If yearly profit is the difference between total revenue and production costs, determine a selling price s, s ≥ 25, that will maximize the company's yearly profit, P
|
Challenge of using unstructured data approach
: What is the drawback or challenge of using unstructured data approach? Why is that challenge a problem for someone who may want to use this technique?
|