Question 1. A road 300 m long is required to be illuminated by providing 40W fluorescent lamps. The width of the road is 4m. Design a street lighting scheme for obtaining minimum level of illumination of 0.6 lux assuming a mounting height of 9m and a 0.5 coefficient of utilization. (In designing you have to determine the distance between the poles and find out the number of poles required for the given distance.)

Question 2. A light assembly shop, 15m long, 9m wide and 3m up to trusses, is to be illuminated to a level of 200 lux. The utilization and maintenance factors are respectively 0.9 and 0.8. Make a scale drawing of the plan of the shop and set out the required lighting points, assuming the use of tungsten lamps and dispersive metallic reflectors. You may assume a lamp efficiency of 13 lm/W, and spacing height ratio of unity.

Question 3. A room measures 10mX20m and illuminated by 10 lamps of 700W each. It is illuminated semi-directly and the luminous efficiency of each lamp is 14lm/w. Allowing a depreciation factor of 1.7, determine the illumination of the working plane and guess the type of building considering the installation is correct.

Question 4. Given a 50m X 20m drawing room. It is required to illuminate semi-directly by 18W fluorescent lamps having an efficiency of 42 lm/W. Assuming a suitable space height ratio for new installation, estimate the no., rating and disposition of lamps if they to be mounted at 2.5m above the working bench.

Question 5. A hall 30m X 15m height is to be provided with a general illumination of 120lm/m2 Taking a coefficient of utilization of 0.5, depreciation factor 1.4 and appropriate space-height ratio, determine the no. of fluorescent tubes required, their spacing, mounting height and total wattage. Take luminous efficiency of fluorescent tubes as 40lm/W for 80 watt tube.

Question 6. A hall 15m by 20m is to be illuminated to a level of 70 lux. Luminaries having an efficiency of 12lm/w and spacing-height ratio 1.2 are to be suspended 4m above the flour. Estimate the no. of luminaries required and the power of each luminary. Assume a utilization factor of 0.5 and maintenance factor of 0.8. Also lay out the position of the luminaries.

Question 7. A room 7m by 10m is to be used as a general office and must be provided with illumination to a level of 4001x. 150w luminaries are to be installed giving a utilization factor of 0.5 and requiring a maintenance factor of 0.8. Assuming that the efficiency of luminaries is 13lm/w, calculate the no. of luminaries required.

Question 8. A road 300 m long is required to be illuminated by providing 40W fluorescent lamps.

The width of the road is 4m. Design a street lighting scheme for obtaining minimum level of illumination of 0.6 lux assuming a mounting height of 9m and a 0.5 coefficient of utilization.

(In designing you have to determine the distance between the poles and find out the number of poles required for the given distance.)

Reference no: EM131305883

Questions Cloud

Describe any social-environmental-psychological : Describe the violent female offender you selected. Describe any social, environmental, psychological, and/or biological factors that may have contributed to the crime and explain how. Support your Assignment with specific references to all resources ..
What should the nsa have been doing in the case and why : What should the NSA have been doing in this case, and why? What should Snowden have done, and why? Why and how do you reach the conclusions you do?
Write up the trial balance for the month end of july : Write up the ledger accounts using the "T" format for the above transactions, complete and balance the accounts. Write up the Trial Balance for the month end of July 31, 2015
Global economy threatened by ethnocentrism : How strong a factor is ethnocentrism in war-torn regions of the world, including Northern Ireland, the Middle East, northern India, central Africa, and the Balkans? Is the trend toward a global economy threatened by ethnocentrism? Explain.
Calculate the no of luminaries required : Determine the distance between the poles and find out the number of poles required for the given distance - determine the illumination of the working plane and guess the type of building considering the installation is correct.
Describe a recent promotion experience : Describe a recent promotion experience. (As seen on television, mail, radio, Internet, sales person, outdoor/ signage, prints, etc.)Identify each of the Communication Process elements to that promotion. Provide evidence by example.Discuss whether ..
What equipment would you need to collect data : Design a recording form for this behavior and explain how you would use this form to gather data on this behavior. What equipment would you need to collect data? In what units would your measure be expressed
How does the media influence the public or public opinion : How does the media influence the public or public opinion? How does your media outlet choice (from where you get your political information) impact your opinion or access to quality information?
What can small businesses do to attract a loyal customer : Identify the major attributes and benefits to the customer's value.Assess the qualitative importance of the different attributes and benefits.Assess the companies and competitors performances on the different customer values against their rated impor..

Reviews

len1305883

12/9/2016 12:33:44 AM

A road 300 m long is required to be illuminated by providing 40W fluorescent lamps. The width of the road is 4m. Design a street lighting scheme for obtaining minimum level of illumination of 0.6 lux assuming a mounting height of 9m and a 0.5 coefficient of utilization. (In designing you have to determine the distance between the poles and find out the number of poles required for the given distance.) and example questions 1-7

Write a Review

Electrical Engineering Questions & Answers

  Lithium ion battery technology

The paper includes Lithium ion battery technology with its advantages and disadvantages. The paper discusses about the Lithium air battery in which detailed reactions of Lithium with air including nonaqueous as well as aqueous are given.

  Power transformers and tariffs

Construction of different types of power transformer, significant energy savings

  Paper on orthogonal frequency-division multiplexing

This document is shown a paper on Orthogonal frequency-division multiplexing with advantages, disadvantages and uses.

  Function of the hmi in a scada system

This assignment contains electronics engineering questions like State the commonly found components of a SCADA (Supervisory control and data acquisition) system. and decribe the function of the HMI in a SCADA system.

  Resultant waveform of the odd harmonic series

Prepare an Excel graph showing the individual components and summated resultant waveform of the odd harmonic series resulting in an approximate square wave.

  Explain scada system

Explain the function of the HMI in a SCADA system.

  Design a 2-digit 24 second shot-clock

Design a 2-digit 24 second "shot-clock" countdown timer with pushbutton controller.

  Model a discrete-time system

To understand di erent signal models To be able to model a discrete-time system and design simple signal processing algorithms.

  Draw a relay construction diagram

Draw a relay construction diagram and briefly explain the operation of a relay.

  Frequency division multiplexing

Write a short technical report on Frequency Division Multiplexing

  Impact of electron energy

Briefly discuss the impact of electron energy, electron current and target on the Bremsstrahlung generated.

  Traffic light controller

The schematic of the traffic light controller

Free Assignment Quote

Assured A++ Grade

Get guaranteed satisfaction & time on delivery in every assignment order you paid with us! We ensure premium quality solution document along with free turntin report!

All rights reserved! Copyrights ©2019-2020 ExpertsMind IT Educational Pvt Ltd